Accuracy of temperature measurement in the cardiopulmonary bypass circuit.

نویسندگان

  • Richard F Newland
  • Andrew J Sanderson
  • Robert A Baker
چکیده

Oxygenator arterial outlet blood temperature is routinely measured in the cardiopulmonary bypass (CPB) circuit as a surrogate for the temperature of the arterial blood delivered to sensitive organs such as the brain. The aim of this study was to evaluate the accuracy of the temperature thermistors used in the Terumo Capiox SX25 oxygenator and to compare the temperature measured at the outlet of the oxygenator using the Capiox CX*TL Luer Thermistor with temperatures measured at distal sites. Five experimental stages were performed in vitro to achieve this aim. Under our experimental conditions, the luer thermistors accurately measured the temperature as referenced by a precision thermometer. In the CPB circuit, the difference between arterial outlet and reference thermometer temperature varied with outlet temperature over-reading at low temperatures and under reading at high temperatures. There was negligible heat loss (-0.4+/-0.1degrees C) measured at 4.5 m from the arterial outlet. The Terumo Capiox CX*TL Luer Thermistor is an accurate and reliable instrument for measuring temperature when incorporated into the Capiox Oxygenator. The accuracy in the measurement of temperature using these thermistors is affected by the thermistor immersion depth. Under reading of the arterial blood temperature by approximately 0.5 degrees C should be considered at normothermic temperatures, to avoid exceeding the maximum arterial blood temperature as described by institutional protocols. The accuracy of blood temperature measurements should be considered for all oxygenator arterial outlet temperature probes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Temperature inaccuracies during cardiopulmonary bypass.

Cerebral hyperthermia caused by perfusate temperature greater than 37 degrees C during the rewarming phase of CPB has been linked to postoperative neurologic deficits. The purpose of this study was to determine the accuracy of the coupled temperature measurement system and the CDI 500 arterial temperature sensor. Seventeen patients undergoing CPB were divided into four groups, each with a diffe...

متن کامل

Evaluation of five in-line hematocrit monitors.

Monitoring the hematocrit is essential during cardiopulmonary bypass for efficacious administration of blood products. The purpose of this study was to evaluate five cardiopulmonary bypass in-line monitors designed to display continuous hematocrit or hemoglobin values. The devices were evaluated for accuracy using an in vitro circuit primed with human blood while randomizing hematocrit, blood f...

متن کامل

The Effect of ringer Lactate as the Priming Solution of the Cardiopulmonary by Pass Circuit on Plasma Potassium Levels after Open Heart Surgery in Children

Background: Conduct of cardiopulmonary bypass (CPB) due to the higher volume of priming solution in comparison to the total blood volume in children requires careful consideration. Recently attention has been focused on the potential risk of hyperkalemia in these patients. Given its significant effects on cardiac rhythm, hyperkalemia is considered a medical emergency. In this cross-sectional st...

متن کامل

Problems of Cold Agglutinins in Cardiac Surgery: How to Manage Cardiopulmonary Bypass and Myocardial Protection

Cold agglutinins are of unique relevance in cardiac surgerybecause of the use of hypothermic cardiopulmonary bypass (CPB). Cold autoimmune diseases are defined by the presence of abnormal circulating proteins (usually IgM or IgA antibodies) that agglutinate in response to a decrease in body temperature. These disorders include cryoglobulinemia and cold hemagglutinin disease.Immunoglobulin M aut...

متن کامل

SCIENTIFIC PRESENTATION AWARD Clinical Accuracy of Continuous Hemoglobin Oxygen Saturation Monitoring Devices

-----------------Three devices used to measure hemoglobin oxygen saturation in the extracorporeal circuit were studied and compared to a control. The Baxter Bentley OxySat, Oximetrix Accusat, and the Radiometer ABL4 blood gas monitor were compared to a control, the IL 282 CoOximeter. Fifty one sample points were obtained during all phases of cardiopulmonary bypass with results as follows: TABLE...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 37 1  شماره 

صفحات  -

تاریخ انتشار 2005