Dual-energy subtraction for contrast-enhanced digital breast tomosynthesis

نویسندگان

  • Ann-Katherine Carton
  • Christer Ullberg
  • Andrew D.A. Maidment
چکیده

We have developed a dual-energy subtraction technique for contrast-enhanced breast tomosynthesis. The imaging system consists of 48 photon-counting linear detectors which are precisely aligned with the focal spot of the x-ray source. The x-ray source and the digital detectors are translated across the breast in a continuous linear motion; each linear detector collects an image at a distinct angle. A pre-collimator is positioned above the breast and defines 48 fanshaped beams, each aligned with a detector. Lowand high-energy images are acquired in a single scan; half of the detectors capture a low-energy beam and half capture a high-energy beam, as alternating fan-beams are filtered to emphasize low and high energies. Imaging was performed with a W-target at 45 and 49 kV. Phantom experiments and theoretical modeling were conducted. Iodine images were produced with weighted logarithmic subtraction. The optimal tissue cancellation factor, wt, was determined based on simultaneous preservation of the iodine signal and suppression of simulated anatomic background. Optimal dose allocation between lowand high-energy images was investigated. Mean glandular doses were restricted to ensure clinical relevance. Unlike other dual-energy approaches, both spectra must have the same peak energy in this system design. We have observed that wt is mainly dependent on filter combination and varies only slightly with kV and breast thickness, thus ensuring a robust clinical implementation. Optimal performance is obtained when the dose fraction allocated to the high energy images ranges from 0.55 to 0.65. Using elemental filters, we have been able to effectively suppress the anatomic background.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Segmentation methods for breast vasculature in dual-energy contrast-enhanced digital breast tomosynthesis

Dual-energy contrast-enhanced digital breast tomosynthesis (DE CE-DBT) uses an iodinated contrast agent to image the three-dimensional breast vasculature. The University of Pennsylvania has an ongoing DE CE-DBT clinical study in patients with known breast cancers. The breast is compressed continuously and imaged at four time points (1 pre-contrast; 3 post-contrast). DE images are obtained by a ...

متن کامل

2D and 3D registration methods for dual-energy contrast-enhanced digital breast tomosynthesis

Contrast-enhanced digital breast tomosynthesis (CE-DBT) uses an iodinated contrast agent to image the threedimensional breast vasculature. The University of Pennsylvania is conducting a CE-DBT clinical study in patients with known breast cancers. The breast is compressed continuously and imaged at four time points (1 pre-contrast; 3 postcontrast). A hybrid subtraction scheme is proposed. First,...

متن کامل

Dual-energy contrast-enhanced digital breast tomosynthesis--a feasibility study.

Contrast-enhanced digital breast tomosynthesis (CE-DBT) is a novel modality for imaging breast lesion morphology and vascularity. The purpose of this study is to assess the feasibility of dual-energy subtraction as a technique for CE-DBT (a temporal subtraction CE-DBT technique has been described previously). As CE-DBT evolves, exploration of alternative image acquisition techniques will contri...

متن کامل

Temporal Subtraction Versus Dual-Energy Contrast-Enhanced Digital Breast Tomosynthesis: A Pilot Study

In contrast-enhanced DBT (CE-DBT), breast lesion vascularity is characterized by administrating an iodinated vascular contrast agent. In this work, a combined temporal and dual-energy (DE) subtraction CE-DBT technique was performed in 4 women with mammographic findings that warranted biopsy. Lesion enhancement characteristics and morphology obtained with both CE-DBT techniques are correlated to...

متن کامل

Dual-Energy Subtraction X-Ray Digital Tomosynthesis: Basic Physical Evaluation

The present study was performed to determine the potential of applying dual-energy subtraction (DES) digital tomosynthesis to basic physical evaluations. Volumetric X-ray DES digital tomosysnthesis was used to obtain an image of a detectability phantom (an artificial lesion). The image quality of DES digital tomosynthesis was compared to that of DES radiography. The purpose of this study was to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007