Comparison of extraction procedures for the determination of arsenic and other elements in lobster tissue by inductively coupled plasma mass spectrometry.

نویسندگان

  • Judith A Brisbin
  • Joseph A Caruso
چکیده

A variety of extraction procedures were evaluated for the extraction of arsenic and other analytes from lobster tissue samples using inductively coupled plasma mass spectrometry (ICP-MS) detection. Soxhlet, room temperature mixing, sonication, microwave assisted, supercritical carbon dioxide and subcritical water extractions were evaluated for a variety of solvent systems and optimum conditions determined using a partially defatted Lobster Hepatopancreas marine certified reference material, TORT-2 (National Research Council of Canada). The solubility trends and solvents into which the analytes extracted gave an indication as to the polar/non-polar nature of the compounds present. Analytes that prefer water are probably more polar or inorganic, while those preferring methanol solutions are less polar or organic in nature. Arsenic, cadmium, cobalt, molybdenum and selenium were probably all present in TORT-2 in both polar inorganic and non-polar organic forms. While TORT-2 may have contained similar amounts of selenium in both forms, the results suggested that more of the arsenic was present as less polar or more organic compounds, and cobalt existed mainly as more polar or inorganic species. Most of the extraction techniques suggested that, although there may be some less polar organic forms present, more of the cadmium was probably present as polar inorganic compounds. Additionally, most techniques indicated that molybdenum was possibly all less polar or more organic in nature. In general, microwave assisted extraction (MAE) yielded comparable or improved recoveries for all of the analytes monitored and usually required less solvent. Additionally, MAE proved to be the mildest, fastest, least complicated and most reproducible extraction technique evaluated. MAE at 75 degrees C for 2 min exposure time yielded quantitative recovery of arsenic from TORT-2. These conditions were evaluated for lobster tissue samples purchased from a local restaurant. Separate evaluation of the lobster meat and organs resulted in quantitative recoveries of arsenic from both tissue samples. The results indicated that the extraction efficiencies might have some dependence upon the extraction technique, extraction conditions, analyte, solvent, and sample matrix.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry

In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...

متن کامل

Trace Metals and Major Elements in Sediments of the Northern Persian Gulf

The concentrations of sixteen elements and organic carbon were determined in 78 marine sediment samples collected from the Iranian coastal waters of the Persian Gulf. Nine transects perpendicular to the coastline were sampled. Sixteen elements, including As, Ba, Cd, Co, Cu, Mn, Ni, Pb, Zn (trace metals) and Ca, Fe, Mg, Na, P, S, Si (major metals), were determined by Inductively Coupled Plasma M...

متن کامل

Microwave assisted digestion coupled with inductively coupled plasma optical emission spectrometry for determining element concentrations in halophytes

Introduction: This study was carried out to determine elements (Li, Na, K, Mg, Ca, Ba, B, Al, Si, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Ag and P) in the Suaeda vermiculata (S. vermiculata) and Suaeda aegyptiaca (S. aegyptiaca) in three different regions of Southern Iran using inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted acid digestion. Materials and ...

متن کامل

Determination of 137Ba Isotope Abundances in Water Samples by Inductively Coupled Plasma-optical Emission Spectrometry Combined with Least-squares Support Vector Machine Regression

A simple and rapid method for the determination of 137Ba isotope abundances in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES) coupled with least-squares support vector machine regression (LS-SVM) is reported. By evaluation of emission lines of barium, it was found that the emission line at 493.408 nm provides the best results for the determination...

متن کامل

Quantitative and Qualitative Determination of Heavy and Toxic Elements in the Fish Grown in Treated Wastewater and Their Comparison with Other Fish

The elements Fe, Cu, Mn, Zn, Cr, Ni, Pb and Cd were determined in the meat and skin of fish by Atomic Absorption Spectroscopy (AAS). The fish were grown in treated wastewater, Zayanderood river, and fisheries of Flavarjan and Babolsar. Arsenic and mercury in the samples were analyzed by Inductively Coupled Plasma Emission Spectroscopy and Cold Vapor AAS, respectively. The concentration of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 127 7  شماره 

صفحات  -

تاریخ انتشار 2002