Inhibition of surface induced coagulation by preadsorption of albumin-heparin conjugates.
نویسندگان
چکیده
Surface coatings of the albumin-heparin conjugates were developed to improve the blood compatibility of polymeric materials. Glass, PVC, Biomer and cellulose acetate were coated with albumin-heparin conjugate and its adsorption and desorption behavior on glass in particular was studied using 3H and 51Cr radiolabeled conjugates. Precoated materials showed a significant prolongation of the Lee-White clotting time as compared with noncoated ones. It was demonstrated that the prolonged clotting time for pretreated glass was due to surface bound conjugate. Prolonged recalcification times of plasma exposed to glass, Biomer, and PVC were obtained using albumin-heparin conjugate precoated surfaces. Albumin-heparin conjugates with high affinity for antithrombin III gave more prolonged clotting times as low affinity conjugates when used as coatings for glass. This indicates that the behaviour of heparin in preadsorbed conjugates resembles that of heparin in solution.
منابع مشابه
Covalently bound conjugates of albumin and heparin: synthesis, fractionation and characterization.
Covalently bound conjugates of human serum albumin and heparin were prepared as compounds which could improve the blood-compatibility of polymer surfaces either by preadsorption or by covalent coupling of the conjugates onto blood contacting surfaces. The conjugates (10-16 weight % of heparin) were obtained by a condensation reaction between albumin and heparin using 1-ethyl-3-(dimethylaminopro...
متن کاملمطالعه تجربی اثر روشهای مختلف تجویز هپارین در جلوگیری از چسبندگی در التهاب عفونی و غیرعفونی صفاق در خوکچه هندی
Background & Aim: Abdominal surgery may lead to intra-abdominal adhesion. Therefore scientists suggest different methods to prevent this problem. Use of heparin, by its mechanism of coagulation pathway inhibition, is one of these methods. The aim of this study was the comparison of various methods of heparin administration in prevention of post-surgical abdominal adhesion. Materials and Met...
متن کاملHeparinization of gas plasma-modified polystyrene surfaces and the interactions of these surfaces with proteins studied with surface plasmon resonance.
Polystyrene surfaces obtained by spin-coating a solution of polystyrene in toluene on a gold layer were functionalized with carboxylic acid groups by preadsorption of the sodium salt of undecylenic acid, followed by an argon plasma treatment. A conjugate of albumin and heparin (alb-hep) was covalently immobilized onto the functionalized surface via preactivation of carboxylic acid groups with a...
متن کاملInteraction of antithrombin III with preadsorbed albumin-heparin conjugates.
The adsorption of antithrombin III (AT III) onto polystyrene surfaces preadsorbed with albumin or albumin-heparin conjugates was studied using a two step enzyme immuno assay. When AT III-buffer solutions were used, the highest adsorption values were measured on high affinity albumin-heparin conjugate pretreated surfaces. Less AT III adsorption was found on nonfractionated albumin-heparin conjug...
متن کاملInteraction of antithrombin III with surface-immobilized albumin-heparin conjugates.
The interaction between antithrombin III (ATIII) and albumin-heparin conjugates covalently coupled onto carboxylated polystyrene beads either in buffer containing albumin or in plasma was studied using 14C-labeled ATIII. Binding isotherms of ATIII were modeled using a summation of two Langmuir equations. These equations describe the binding of ATIII to two different sets of binding sites, one w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical materials research
دوره 18 8 شماره
صفحات -
تاریخ انتشار 1984