A pseudoepidemic of Legionella infections.

نویسندگان

  • R L Ristagno
  • L D Saravolatz
چکیده

During a six-month period, we observed an increase in the incidence of presumed Legionnaires' disease (LD) due to false-positive direct immunofluorescent antibody (DFA) staining. Contamination of the DFA staining reagents with Legionella appeared to account for our pseudoepidemic. Although a positive DFA stain has been regarded as highly specific for the diagnosis of LD, the clinician must interpret such results with caution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Investigation of the Legionella Pneumophila Infection in Pneumonic Patients in Three Different Infections Hospital Wards in Tehran

Legionella pneumophila is one of the causative agent of pneumonia in human being. In recent years many reports has been come from different parts of world regarding infectivity of this organism. This disease occurs almost because of contamination of air conditioning systems. For the purpose of assessment of the legionella pneumophila in pneumonic patients, 200 specimen from sputum and tracheo-b...

متن کامل

ارتباط آلودگی آب به لژیونلا با عناصر جزئی در سامانه آب بیمارستان‌های منتخب تهران

Background and purpose: Water microelements can influence the growth and colonization of Legionella and infections associated with these bacteria. This research investigated Legionella contamination of water regarding microelements, alkalinity and hardness in selected hospitals of Tehran. Materials and methods: Hundred-fifty samples with 4 L volume were collected from cold and warm water sys...

متن کامل

New Legionella Control Options by UV and Violet LEDs for Hospitals and Care Facilities

Legionella infections caused by contaminated water are a widespread problem worldwide. Discharge lamps like mercury vapor lamps are widely known for the disinfection properties of their radiation, but they suffer technical disadvantages, like high voltages and toxic content, and are, therefore, not suitable for some infection control applications. New high-intensity ultraviolet (UV) an...

متن کامل

Investigation of Legionella Pneumophila bacteria in hospital water supply systems

Introduction: Legionella Pneumophila bacteria is known as one of the most important nosocomial infections and the most common cause of death in patients. This study was aimed to identify Legionella Pneumophila bacteria in hospital water supply systems. Material and Methods: This descriptive cross-sectional study was performed to identify Legionella pneumophila in hot and cold-water systems of i...

متن کامل

مقایسه حساسیت پرایمرهای مختلف اختصاصی ناحیه  16srDNAدر شناسایی گونه‌های باکتری لژیونلا در نمونه‌های آبی

Background and Objectives: Legionella are gram-negative bacteria widely dispersed in natural and man-made water sources. Some Legionella species are pathogenic and could cause respiratory infections. Cultivation technique is the conventional method for the detection of Legionella spp. in aquatic samples. However, the method has low sensitivity and require prolonged incubation period. Theref...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 88 3  شماره 

صفحات  -

تاریخ انتشار 1985