Stress Sensitivity of Mercury Injection Measurements
نویسندگان
چکیده
Many petrophysical properties (e.g. permeability, electrical resistivity etc.) of tight rocks are very stress sensitive. However, most mercury injection measurements are made using an instrument that does not apply a confining pressure to the samples. Here we further explore the implications of the use and analysis of data from mercury injection porosimetry or mercury capillary pressure measurements (MICP). Two particular aspects will be discussed. First, the effective stress acting on samples analysed using standard MICP instruments (i.e. Micromeritics Autopore system) is described. Second, results are presented from a new mercury injection porosimeter that is capable of injecting mercury at up to 60,000 psi into 1.5 or 1 in core plugs while keeping a constant net stress up to 15,000 psi. This new instrument allows monitoring of the electrical conductivity across the core during the test so that an accurate threshold pressure can be determined. Although no external confining pressure is applied (unconfined) when using the standard MICP instrument, this doesn’t mean that the measurements can be considered as unstressed. Instead, the sample is under isostatic compression by the mercury until it enters the pore space of the sample. As an approximation, the stress that the mercury places on the sample is equal to its threshold pressure. Thus, the permeability calculated from standard MICP data is equivalent to that measured at its threshold pressure. Not all the samples have the same stress dependency thus comparing measured permeabilities at a single stress with values calculated from standard MICP data, corresponding at different threshold pressures, can lead to erroneous correlations. Therefore, the estimation of permeabilities from standard MICP data can be flawed and uncertain unless the stress effect is included. Results obtained from the new mercury injection system, porosimeter under net stress, are radically different from those obtained from standard MICP instruments such as the Autopore IV. In particular, the measurements at reservoir conditions produce threshold pressures that are three times higher and pore throat sizes that are 1/3rd of those measured by the standard MICP instrument. The results clearly indicate that calculating capillary height functions, sealing capacity, etc. from the standard instrument can lead to large errors that can have significant impact on subsurface characterization.
منابع مشابه
SELF-INDUCED FOREIGN BODY GRANULOMAS DUE TO INJECTION OF ELEMENTAL MERCURY
A 24-year-old girl injected approximately I ml of elemental mercury from a few broken thermometers to her right cubital fossa. It led to the formation of a tumoral lesion which was erythematous, lobulated, painful, with secretory sinuses in the injected area. Biopsy showed foreign body granulomas with metallic mercury that appeared as dark opaque globules. X-rays showed metallic densities i...
متن کاملConstruction of a Carbon Paste Electrode Based on Novel Thiolated Ligand Capped Gold Nanoparticles for Determination of Trace Amounts of Mercury(II)
In the present study, a simple electrochemical sensor for trace determination of Hg(II) ions in aqueous solutions was introduced. The proposed sensor was designed by incorporation of the 4-methyl-piperidine-carbodithioate capped gold nanoparticles (GNPs) into the carbon paste electrode (CPE), which provides a remarkably improved sensitivity for stripping voltammetric determination of Hg(II). Di...
متن کاملMicroelectrode arrays: application in batch-injection analysis
The application of microelectrode arrays in electrochemical batch-injection analysis, injection volumes 100 ml, has been investigated using a random array of microdisks (RAM) electrode made with carbon ®bres. Preliminary batch-injection experiments involving hexacyanoferrate(II) oxidation, using ®xed-potential amperometry and cyclic voltammetry, showed the expected lesser dependence on injectio...
متن کاملExtraction-Fluorimetric Determination of Trace Amounts of Mercury by 1,10-Diaza-18-Crown-6 and Rose Bengal
A simple and sensitive extraction-fluorimetric method for the determination of mercury is reported. The method is based on the quantitative extractionof a ternary crown-mercury-rose Bengal complex into chloroform at pH 10 followed by fluorimetric measurements at 580 nm. A linear working range from 0.05 to 2.00 mg/mL is obtained. The relative standard deviation for 1.0 </em...
متن کاملمقایسه دمای اندازه گیری شده بدن به وسیله ترمومتر جیوه ای و دیجیتالی
Background and Aim: Mercury is a dangerous substance for human health and mercury thermometers are major pollutant for environment. Using less dangerous and less expensive devices like digital thermometer can be an alternative for mercury thermometers. The aim of this study was to compare the body temperature measurement by mercury and digital thermometer. Material and Method : In this desc...
متن کامل