Intrapartum heart rate ambiguity: a comparison of cardiotocogram and abdominal fetal electrocardiogram with maternal electrocardiogram.
نویسندگان
چکیده
OBJECTIVE/AIMS To investigate the presence of signal ambiguity of intrapartum fetal heart rate (FHR) monitoring during delivery by comparing simultaneous cardiotocogram (CTG), abdominal fetal electrocardiogram (ECG) with continuous maternal ECG. METHODS A total of 144 simultaneous CTG (Corometrics 250 series), abdominal fetal ECG (Monica -AN24™) and maternal ECG (Monica AN24™) recordings were evaluated. MAIN OUTCOME MEASURES When the FHR is within 5 bpm of the maternal heart rate (MHR) acquired from the ECG, it is classified as 'MHR/FHR ambiguity'. Statistical analyses were performed with Fisher's exact test and the Wilcoxon signed-rank test. RESULTS Comparison of abdominal fetal ECG against CTG demonstrates significantly less 'MHR/FHR ambiguity' in both the first stage (mean 0.70 vs. 1.22%, p < 0.001) and second stage of labour (mean 3.30 vs. 6.20%, p < 0.001). CONCLUSION Intrapartum FHR monitoring in daily practice via the CTG modality provides significantly more 'MHR/FHR ambiguity' than abdominal fetal ECG, which also provides additional information on the MHR.
منابع مشابه
Plymouth randomized control trial of cardiotocogram only versus ST waveform plus cardiotocogram for intrapartum monitoring in 2400 cases.
OBJECTIVE The physiology of changes in the ST waveform of the fetal electrocardiogram has been elucidated in extensive animal and human observational studies. A combination of heart rate and ST waveform analysis might improve the predictive value of intrapartum monitoring. Our purpose was to compare operative intervention and neonatal outcome in labors monitored by the conventional cardiotocogr...
متن کاملINTELLIGENT TECHNIQUE OF CANCELING MATERNAL ECG IN FECG EXTRACTION
In this paper, we propose a technique of artificial intelligence called adaptive neuro fuzzy inference system (ANFIS) for canceling maternal electrocardiogram (MECG) in fetal electrocardiogram extraction (FECG).This technique is used to estimate the MECG present in the abdominal signal of a pregnant woman. The FECG is then extracted by subtracting the estimated MECG from the abdominal signal. P...
متن کاملSolution of Controversy in Fetal Heart Rate Patterns
Fetal well-being was estimated by the enlargement of maternal abdomen, palpation of fetus on the abdomen, maternal perception of fetal kicking, and listening to fetal heart sound with obstetric stethoscope, in old age. Antique diagnosis of fetal life was fetal QRS found on limb lead electrocardiogram (ECG) studied by Cremer, which was progressed to fetal ECG amplifier composed of vacuum tube re...
متن کاملAutomated Identification of Abnormal Cardiotocograms Using Neural Network Visualization Techniques
The cardiotocogram (CTG) is a display of the fetal heart rate and maternal uterine activity over time. An automated system for CTG analysis can be used as a decision support tool in a clinical setting. We present an automated system for the identification of abnormal patterns in the intrapartum (labor) CTG. We extract discriminating features from the CTG and then use techniques based upon the N...
متن کاملExtraction of clinical information from the non-invasive fetal electrocardiogram
Extraction of Clinical Information from the Non-Invasive Fetal Electrocardiogram Joachim Behar Thesis submitted for the degree of Doctor of Philosophy Balliol college Michaelmas 2014 Estimation of the fetal heart rate (FHR) has gained interest in the last century; low heart rate variability has been studied to identify intrauterine growth restricted fetuses (prepartum), and abnormal FHR pattern...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Gynecologic and obstetric investigation
دوره 75 2 شماره
صفحات -
تاریخ انتشار 2013