Non-Invasive Respiratory Impedance Enhances Cerebral Perfusion in Healthy Adults

نویسندگان

  • Christopher G. Favilla
  • Ashwin B. Parthasarathy
  • John A. Detre
  • Arjun G. Yodh
  • Michael T. Mullen
  • Scott E. Kasner
  • Kimberly Gannon
  • Steven R. Messé
چکیده

Optimization of cerebral blood flow (CBF) is the cornerstone of clinical management in a number of neurologic diseases, most notably ischemic stroke. Intrathoracic pressure influences cardiac output and has the potential to impact CBF. Here, we aim to quantify cerebral hemodynamic changes in response to increased respiratory impedance (RI) using a non-invasive respiratory device. We measured cerebral perfusion under varying levels of RI (6 cm H2O, 9 cm H2O, and 12 cm H2O) in 20 healthy volunteers. Simultaneous measurements of microvascular CBF and middle cerebral artery mean flow velocity (MFV), respectively, were performed with optical diffuse correlation spectroscopy and transcranial Doppler ultrasound. At a high level of RI, MFV increased by 6.4% compared to baseline (p = 0.004), but changes in cortical CBF were non-significant. In a multivariable linear regression model accounting for end-tidal CO2, RI was associated with increases in both MFV (coefficient: 0.49, p < 0.001) and cortical CBF (coefficient: 0.13, p < 0.001), although the magnitude of the effect was small. Manipulating intrathoracic pressure via non-invasive RI was well tolerated and produced a small but measurable increase in cerebral perfusion in healthy individuals. Future studies in acute ischemic stroke patients with impaired cerebral autoregulation are warranted in order to assess whether RI is feasible as a novel non-invasive therapy for stroke.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Changes in cerebral physiology with ageing assessed by respiratory-calibrated MRI

Purpose: Recently, respiratory-calibrated MRI methods capable of providing a non-invasive, quantitative assessment of cerebral physiology have been developed. Although differing slightly in detail, the aim of these methods is the same: to calibrate the MRI signal using a combination of hyperoxic and hypercapnic gas stimuli, and thereby allow quantification of brain energy metabolism and perfusi...

متن کامل

The role of relative cerebral blood volume obtained from Perfusion Weighted Imaging-MRI in glioma tumor grading before surgery

Introduction: Glioma is the most common type of brain malignancy among adults. Treatment for this type of tumor involves surgery, radiotherapy, and in higher grades, including chemotherapy. The precise grading of the tumor is critical for treatment planning and prognosis determining. Considering the possibility of problems such as errors in tissue sampling during surgery, as we...

متن کامل

Cardiac output measured by transthoracic impedance cardiography at rest, during exercise and at various lung volumes.

1. Cardiac output measured by transthoracic impedance cardiography has been compared with simultaneous measurements made by the indirect Fick CO2 rebreathing method in nine adults and 14 children. All were healthy normal volunteers. Sixty-six comparisons were made at rest and during steady exercise at work loads up to 100 W. 2. Impedance measurements of cardiac output were consistently higher t...

متن کامل

Use of the laryngeal tube as a dedicated airway during tracheal intubation.

687±92 2 Dewey RC, Pieper HP, Hunt WE. Experimental cerebral hemodynamics. Vasomotor tone, critical closing pressure, and vascular bed resistance. J Neurosurg 1974; 41: 597±606 3 Aaslid R, Lundar T, Lindegaard K-F, Nornes H. Estimation of cerebral perfusion pressure from arterial blood pressure and transcranial Doppler recordings. In: Miller JD, Teasdale GM, Rowan JO, Galbraith SL, Mendelow AD,...

متن کامل

Pulmonary ventilation and perfusion assessed by electrical impedance tomography Experimental studies in pigs

Pulmonary ventilation and perfusion and ventilation/perfusion (V/Q) matching determine gas exchange in every lung unit in the healthy state and in the pathologically altered lung. Mismatch of V and Q lead to hypoxaemia and hypercapnia and monitoring of V/Q relations are thus important in critical illness. This thesis focuses on electrical impedance tomography (EIT) to monitor pulmonary perfusio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2017