Failure-free survival of the Durata defibrillator lead.
نویسندگان
چکیده
AIMS Given design similarities and a common manufacturer, there have been suspicions regarding the Durata™ defibrillator (ICD) lead, in the aftermath of the Riata™ class I recall. We therefore examined the failure-free survival rates of the Durata™ compared with the Riata™ and Sprint Quattro™ ICD leads. METHODS AND RESULTS All patients (n = 2475) implanted with a Durata (n = 828), Riata [n = 627; 8 Fr. (n = 472) and 7 Fr. (n = 155)], or Sprint Quattro (n = 1020) leads at our institution were included and Kaplan-Meier failure-free survival curves were constructed for all leads. Lead failure was defined as electrical malfunction resulting in lead replacement, excluding dislodgements or perforations. Annual electrical failure rates were 0.3%, 1.7, and 0.3% for the Durata, Riata, and Sprint Quattro leads, respectively (P < 0.0001 for the comparison of Durata to Riata and P = 0.1.0 for the comparison of Durata to Sprint Quattro). The failure-free survival of the Durata lead was significantly better than that of the Riata lead (P < 0.0001) and similar to that of the Sprint Quattro (P = 0.94). The 7 Fr. Riata ST lead had better survival compared with the 8 Fr. Riata lead (P = 0.050) and comparable survival with the Durata lead (P = 0.12). CONCLUSION The Durata lead failure-free survival is significantly better than the 8 Fr. Riata, albeit at a shorter follow-up time. Riata and comparable with that of the 7 Fr. Riata ST and the Sprint Quattro ICD leads. These data provide an insight into the mechanism of electrical failure of Riata leads and have implications for patient management.
منابع مشابه
A case of Durata ICD lead coil externalization: Inside-out lead abrasion?
The St Jude Medical Durata lead was produced in response to the recalled Riata and Riata ST leads in November 2011 after concerns of lead durability and inside-out abrasion. In order to protect against this susceptibility, the Riata ST Optim and Durata leads were coated with an abrasionresistant layer of silicone–polyurethane copolymer (Optim) tubing. We report a case of Durata lead extraction ...
متن کاملTransvenous Implantable Cardioverter‐Defibrillator (ICD) Lead Performance: A Meta‐Analysis of Observational Studies
BACKGROUND Despite the widespread use of implantable cardioverter-defibrillators (ICDs) in clinical practice, concerns exist regarding ICD lead durability. The performance of specific lead designs and factors determining this in large populations need clarification. METHODS AND RESULTS The Medline, Embase, and Cochrane Collaboration databases were searched for studies including ≥2 of the most...
متن کاملFailure of a novel silicone–polyurethane copolymer (Optim™) to prevent implantable cardioverter-defibrillator lead insulation abrasions
AIM The purpose of this study was to determine if Optim™, a unique copolymer of silicone and polyurethane, protects Riata ST Optim and Durata implantable cardioverter-defibrillator (ICD) leads (SJM, St Jude Medical Inc., Sylmar, CA, USA) from abrasions that cause lead failure. METHODS AND RESULTS We searched the US Food and Drug Administration's (FDA's) Manufacturers and User Device Experienc...
متن کاملDelayed cardiac perforation of the Durata implantable cardioverter-defibrillator lead more than 1 year after implantation
Introduction The rate of implantable cardioverter-defibrillator (ICD) lead perforations has been reported to be in the range of 0.6%– 5.2%, with the majority of cases occurring within 1 month of implantation. However, isolated reports of delayed ICD lead perforations occurring more than 1 year and up to 3 years after implantation have been described. Here, we present a case of a patient with a ...
متن کاملTransvenous Implantable Cardioverter-Defibrillator Lead Reliability: Implications for Postmarket Surveillance
BACKGROUND As implantable cardioverter-defibrillator technology evolves, clinicians and patients need reliable performance data on current transvenous implantable cardioverter-defibrillator systems. In addition, real-world reliability data could inform postmarket surveillance strategies directed by regulators and manufacturers. METHODS AND RESULTS We evaluated Medtronic Sprint Quattro, Boston...