In vitro haemocompatibility of a novel bioprosthetic total artificial heart.

نویسندگان

  • Piet Jansen
  • Willem van Oeveren
  • Antoine Capel
  • Alain Carpentier
چکیده

OBJECTIVES The CARMAT total artificial heart (TAH) is an implantable, electro-hydraulically driven, pulsatile flow device with four bioprosthetic valves. Its blood-pumping surfaces consist of processed bioprosthetic pericardial tissue and expanded polytetrafluorethylene (ePTFE), potentially allowing for the reduction of anti-coagulation. This pre-clinical study assessed the in vitro haemocompatibility of these surfaces. METHODS Coupons of pericardial tissue and ePTFE were placed in closed tubular circuits filled with 12.5 ml of fresh human blood exposed to the pulsatile flow at 120 ml/min for 4 h (37°C). Silicone- and heparin-coated polyvinyl chloride (PVC) tubes served as positive and negative controls, respectively. Fresh blood from six donors was used to fill four sets of 12 circuits. Blood samples were taken at baseline and from each circuit after 4 h. Coupons of materials were examined with scanning electron microscopy. RESULTS The platelet count was 202 ± 45 10(9) l(-1) at baseline. Four hours after circulation, the platelet counts were 161 ± 30 10(9) l(-1) (compared with baseline, P = 0.0207) for pericardial tissue, 162 ± 35 10(9) l(-1) (P = 0.0305) for ePTFE and 136 ± 42 10(9) l(-1) for positive controls (P = 0.0021). Baseline plasma fibrinogen was 2.9 ± 0.5 mg/dl compared with 3.0 ± 0.5 mg/dl for pericardial tissue and 3.1 ± 0.7 mg/dl for ePTFE, indicating no marked fibrinogen consumption. Thromboxane B2 levels for positive controls were 33.3 ± 8.7 ng/ml compared with 16.2 ± 11.5 ng/ml for pericardial tissue (P = 0.0015) and 15.2 ± 4.7 ng/ml for ePTFE (P < 0.0001). Platelet adhesion was 2.87 ± 1.01 10(9) cm(-2) for positive controls compared with 1.06 ± 0.73 10(9) cm(-2) for pericardial tissue (P < 0.0001) and 0.79 ± 0.75 10(9) cm(-2) for ePTFE (P < 0.0001). Thrombin-antithrombin III complex levels were 3.8 ± 0.5 μg/ml for positive controls compared with 1.9 ± 0.9 for pericardial tissue (P < 0.0001) and 2.1 ± 1.0 for ePTFE (P < 0.0001). With an electro-microscopic examination at ×600, only small depositions of platelets, erythrocytes and fibrin were noticed on the pericardial tissue samples and ePTFE samples. Silicone surfaces showed marked areas of thrombi, and PVC tubings a thin protein layer. CONCLUSIONS Haemocompatibility of the TAH blood-contacting surfaces was confirmed by in vitro studies showing a limited consumption of fibrin, limited thromboxane B2 release and platelet adhesion, and minor blood cell depositions on the surfaces. These results will be validated in clinical studies, with the aim of reducing anti-coagulation when using the CARMAT TAH.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Animal studies with the Carmat bioprosthetic total artificial heart.

OBJECTIVES The Carmat bioprosthetic total artificial heart (TAH) contains bioprosthetic blood-contacting surfaces, and is designed for orthotopic cardiac replacement. In preparation for clinical studies, we evaluated the TAH performance and its effects on end-organ function in an animal model. METHODS Twelve female Charolais calves, 2-3 months of age and weighing 102-122 kg, were implanted wi...

متن کامل

Trans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)

Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...

متن کامل

Surface modification of polyurethane films by plasma and ultraviolet light to improve haemocompatibility for artificial heart valves.

Prosthetic cardiac valves implantation is a common procedure used to treat heart valve diseases. Although there are different prostheses already available in the market (either mechanical or bioprosthetic), their use presents several problems, specifically concerning thrombogenicity and structural failure. Recently, some progresses have been achieved in developing heart valves based on syntheti...

متن کامل

Phosphonated polyurethanes that resist calcification.

Cardiovascular implant mineralization involving bioprosthetic materials, such as glutaraldehyde cross linked porcine aortic valves or synthetic materials such as polyurethanes, is an important problem that frequently leads to clinical failure of bioprosthetic heart valves, and complicates long-term experimental artificial heart device implants. Novel, proprietary, calcification resistant polyet...

متن کامل

Patients' observations of bioprosthetic valve failure: "my heart is honking, doctor".

Audible cardiac murmurs are uncommon and may indicate severe native valve dysfunction. In six patients with bioprosthetic mitral valves audible honking systolic murmurs suddenly developed. Doppler echocardiography showed characteristic striated regurgitant signals. At operation each prosthesis had torn cusps. New audible murmurs and striated Doppler signals originating from mitral bioprosthetic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 41 6  شماره 

صفحات  -

تاریخ انتشار 2012