Calibration of spectra from dispersive XAS beamlines.

نویسندگان

  • M P Ruffoni
  • R F Pettifer
چکیده

The DXAS Calibration computer program provides a quantitative and automated solution to the problem of calibrating spectra from dispersive XAS beamlines. Such spectra, obtained in arbitrary energy units, are calibrated with respect to the absorption features of a supplied reference spectrum, which has been obtained under similar conditions on a calibrated beamline. In addition to basic energy coordinate transformation parameters, DXAS Calibration supplies instrument corrections to compensate for mismatches in instrument response functions between the dispersive and reference beamlines.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution molybdenum K-edge X-ray absorption spectroscopy analyzed with time-dependent density functional theory.

X-ray absorption spectroscopy (XAS) is a widely used experimental technique capable of selectively probing the local structure around an absorbing atomic species in molecules and materials. When applied to heavy elements, however, the quantitative interpretation can be challenging due to the intrinsic spectral broadening arising from the decrease in the core-hole lifetime. In this work we have ...

متن کامل

Energy Dispersive XAFS: Characterization of Electronically Excited States of Copper(I) Complexes

Energy dispersive X-ray absorption spectroscopy (ED-XAS), in which the whole XAS spectrum is acquired simultaneously, has been applied to reduce the real-time for acquisition of spectra of photoinduced excited states by using a germanium microstrip detector gated around one X-ray bunch of the ESRF (100 ps). Cu K-edge XAS was used to investigate the MLCT states of [Cu(dmp)2](+) (dmp =2,9-dimethy...

متن کامل

Chemical Modification of Nanosilica Toward Dispersive Solid Phase Extraction of Trace Triazine Herbicides from Environmental Water Samples

An easy and fast pathway in preparation of organo-functionalized silica in nanosize range withphenyl-terminated group via co-condensation method is reported. Fourier transform infrared(FTIR) spectra confirmed the grafting process and scanning electron microscopy (SEM) imagecorroborated formation of nanosized material. Applicability of phenyl-modified nanosilica wasexamined as a sorbent in dispe...

متن کامل

Intrinsic deviations in fluorescence yield detected x-ray absorption spectroscopy: the case of the transition metal L2,3 edges

Fluorescence yield (FY) detected x-ray absorption spectra (XAS) of 3d transition metal ions are calculated from the integrated 2p3d resonant x-ray emission spectra. The resulting FY-XAS spectra are compared with the normal XAS spectra corresponding to the absorption cross section and significant deviations between the two spectra are found. This implies that the assumption that the FY-XAS spect...

متن کامل

Intrinsic deviations in fluorescence yield detected x-ray absorption spectroscopy: the case of the transition metal L₂,₃ edges.

Fluorescence yield (FY) detected x-ray absorption spectra (XAS) of 3d transition metal ions are calculated from the integrated 2p3d resonant x-ray emission spectra. The resulting FY-XAS spectra are compared with the normal XAS spectra corresponding to the absorption cross section and significant deviations between the two spectra are found. This implies that the assumption that the FY-XAS spect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of synchrotron radiation

دوره 13 Pt 6  شماره 

صفحات  -

تاریخ انتشار 2006