Comparison measurements of low-pressure between a laser refractometer and ultrasonic manometer.
نویسندگان
چکیده
We have developed a new low-pressure sensor which is based on the measurement of (nitrogen) gas refractivity inside a Fabry-Perot cavity. We compare pressure determinations via this laser refractometer to that of well-established ultrasonic manometers throughout the range 100 Pa to 180 000 Pa. The refractometer demonstrates 10(-6) ⋅ p reproducibility for p > 100 Pa, and this precision outperforms a manometer. We also claim the refractometer has an expanded uncertainty of U(pFP) = [(2.0 mPa)(2) + (8.8 × 10(-6) ⋅ p)(2)](1/2), as realized through the properties of nitrogen gas; we argue that a transfer of the pascal to p < 1 kPa using a laser refractometer is more accurate than the current primary realization.
منابع مشابه
تخمین فشار متوسط شریانی توسط پایش تهاجمی فشار شریانی با مانومتر
Background: Direct monitoring of arterial pressure using a transducer system is not affordable in most operating rooms and ICU wards in Iran. It is, however, possible to use an aneroid manometer instead, but it is not standardized yet, nor studied enough and its measurements may not be interpretable. Methods: To study the correlation of the arterial pressure readings between a manometer and a ...
متن کاملDIFFERENTIAL PRESSURE COMPARISON FROM 20 Pa TO 3 500 Pa BETWEEN CEM - SPAIN AND CENAM - MEXICO
− The results of a comparison in differential pressure between CEM-Spain and CENAM-Mexico are presented here. The comparison was performed in 2008. A high accuracy digital manometer was used for the comparison. The manometer had good behaviour during the period of the comparison, having a small drift which had no effect in the comparison. The results of the measurements showed very good agreeme...
متن کاملComparison of tracheal tube cuff inflation pressure among anesthesia team with different gradual level
Background & Objectives: Tracheal intubation is frequently performed in operating room. Over inflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. On the other hand inadequate cuff pressure increases the risk of aspiration of gastric contents. In this study, the endotracheal tube cuff pressure filled by the anesthesia team has been compared...
متن کاملInvestigation of the ultrasonic welding strength in glass fiber reinforced thermoset polymers with surface preparation method using laser beam
In this research, tensile strength of ultrasonic welded parts made of thermoset polymer-reinforced glass fiber with surface preparation has been investiagted. In order to elevate the adhesion of two surfaces laser grooving method has been applied. Two type of thermoplastic materials including Plymethyl methacrylate (PMMA) and polypropylene (PP) have been used as interlayers. Influences of main ...
متن کاملInvestigation of the ultrasonic welding strength in glass fiber reinforced thermoset polymers with surface preparation method using laser beam
In this research, tensile strength of ultrasonic welded parts made of thermoset polymer-reinforced glass fiber with surface preparation has been investiagted. In order to elevate the adhesion of two surfaces laser grooving method has been applied. Two type of thermoplastic materials including Plymethyl methacrylate (PMMA) and polypropylene (PP) have been used as interlayers. Influences of main ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 87 5 شماره
صفحات -
تاریخ انتشار 2016