Electrical impedance tomography can monitor dynamic hyperinflation in dogs.
نویسندگان
چکیده
We assessed in eight dogs the accuracy with which electrical impedance tomography (EIT) can monitor changes in lung volume by comparing the changes in mean lung conductivity obtained with EIT to changes in esophageal pressure (Pes) and to airway opening pressure (Pao) measured after airway occlusion. The average volume measurement errors were determined: 26 ml for EIT; 35 ml for Pao; and 54 ml for Pes. Subsequently, lung inflation due to applied positive end-expiratory pressure was measured by EIT (delta VEIT) and Pao (delta VPAO) under both inflation and deflation conditions. Whereas delta VPAO was equal under both conditions, delta VEIT was 28 ml greater during deflation than inflation, indicating that EIT is sensitive to lung volume history. The average inflation delta VEIT was 67.7 +/- 78 ml greater than delta VPAO, for an average volume increase of 418 ml. Lung inflation due to external expiratory resistance was measured during ventilation by EIT (delta VEIT,vent) and Pes (delta VPes,vent) and at occlusion by EIT (delta VEIT,occl), Pes, and Pao. The average differences between EIT estimates and delta VEIT,occl were 5.8 +/- 44 ml for delta VEIT,vent and 49.5 +/- 34 ml for delta VEIT,occl. The average volume increase for all dogs was 442.2 ml. These results show that EIT can provide usefully accurate estimates of changes in lung volume over an extended time period and that the technique has promise as a means of conveniently and noninvasively monitoring lung hyperinflation.
منابع مشابه
Applications of Electrical Impedance Tomography in Neurology
Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...
متن کاملReal-time imaging of epileptic seizures in rats using electrical impedance tomography
The presence of multiple or diffuse lesions on imaging is a contraindication to surgery for patients with intractable epilepsy. Theoretically, as a functional imaging technique, electrical impedance tomography (EIT) can accurately image epileptic foci. However, most current studies are limited to examining epileptic spikes and few studies use EIT for real-time imaging of seizure activity. Moreo...
متن کاملXWH - 04 - 1 - 0446 TITLE : Comparison of the Specificity of MR - EIT and Dynamic Contrast - Enhanced MRI in Breast Cancer
In magnetic resonance electrical impedance tomography (MREIT), currents are applied to an object, the resulting magnetic flux density measured using MRI and the conductivity distribution reconstructed using these MRI data. In this study, we assess the ability of MREIT to monitor changes in the conductivity distribution of an agarose gel phantom, using injected current pulses of 900 μA. The phan...
متن کاملLung volume changes during cleaning of closed endotracheal suction catheters: a randomized crossover study using electrical impedance tomography.
BACKGROUND Airway suctioning in mechanically ventilated patients is required to maintain airway patency. Closed suction catheters (CSCs) minimize lung volume loss during suctioning but require cleaning post-suction. Despite their widespread use, there is no published evidence examining lung volumes during CSC cleaning. The study objectives were to quantify lung volume changes during CSC cleanin...
متن کاملComparison of efficacy of long-acting bronchodilators in emphysema dominant and emphysema nondominant chronic obstructive pulmonary disease
BACKGROUND The purpose of this study was to clarify the association between morphological phenotypes according to the predominance of emphysema and efficacy of long-acting muscarinic antagonist and β(2) agonist bronchodilators in patients with chronic obstructive pulmonary disease (COPD). METHODS Seventy-two patients with stable COPD treated with tiotropium (n = 41) or salmeterol (n = 31) wer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of applied physiology
دوره 84 2 شماره
صفحات -
تاریخ انتشار 1998