Performance of direct estradiol immunoassays with human male serum samples.
نویسندگان
چکیده
BACKGROUND Steroid immunoassays originally required solvent extraction, chromatography, and structurally authentic tracers to avoid interference from steroid cross-reactivity and matrix effects. The demand for steroid assays has driven assay simplification, bypassing this triplet of validity criteria to allow use of unextracted serum, which has introduced bias and nonspecificity at low steroid concentrations. We aimed to evaluate the performance of commercial direct estradiol (E2) immunoassays relative to the reference method of LC-MS and compared serum E2 measurements from each assay with biomarkers of estrogen action. METHODS We measured serum E2 in duplicate using 5 commercial direct immunoassays and LC-MS in a nested cohort of 101 healthy, asymptomatic men >40 years old from the Healthy Man Study. For each immunoassay, we evaluated the detectability and distribution of serum E2 measurements, CV, and bias (relative to LC-MS) by Passing-Bablok regression and deviance plots. RESULTS Three assays detected E2 in all samples, whereas E2 was detected in only 53% and 72% of samples by 2 other assays. All 5 assays had positive biases, ranging from 6% to 74%, throughout their ranges. CVs were lower with 4 immunoassays than with LC-MS. LC-MS, but none of the direct immunoassays, correlated with serum testosterone and sex steroid-binding globulin. CONCLUSIONS The positive bias of direct E2 immunoassays throughout their working range reflects the nonspecific effects of steroid cross-reactivity and/or matrix interference arising from the violation of the triplet validity criteria for steroid immunoassay.
منابع مشابه
Measurement of testosterone by immunoassays and mass spectrometry in mouse serum, testicular, and ovarian extracts.
Accurate measurement of testosterone is important for reproductive endocrinology research, but the validity of direct (nonextraction) testosterone immunoassays, developed and validated for human serum, has not been appraised for application to mouse serum or steroidogenic tissue extracts. Testosterone was measured in serum and extracts of testis or ovary from male and female wild-type mice by 2...
متن کاملEffects of Hydroalcoholic Extract of Matricaria chamomilla on Serum Testosterone and Estradiol Levels, Spermatozoon Quality, and Tail Length in Rat
Background: Matricaria chamomilla (chamomile) is a herb used to treat various human illnesses. The present study was conducted to investigate the effects of chamomile extract on spermatozoon quality, serum levels of estradiol and testosterone, and sperm tail length in male adult rat. Methods: Male Sprague-Dawley rats received extract of chamomile (400 mg/kg once daily, orally) during an 8-week...
متن کاملA purification step prior to commercial sensitive immunoassay is necessary to achieve clinical usefulness when quantifying serum 17beta-estradiol in prepubertal children.
OBJECTIVE To test the clinical usefulness of sensitive commercial immunoassays for determination of low 17beta-estradiol concentrations in children. METHODS The lower limit of detection and clinical usefulness (functional sensitivity) of three commercial estradiol immunoassays were validated by use of 500 sera from prepubertal and pubertal children and 55 pooled sera. The three immunoassays c...
متن کاملDirect chemiluminescence immunoassay for estradiol in serum.
In this simple, reliable, fast solid-phase chemiluminescence immunoassay for directly measuring (i.e., without prior extraction) estradiol-17 beta in serum, a monoclonal antibody is used that binds estradiol with high affinity (Ka = 10(10) L/mol), and does not bind other steroids tested, the highest cross reactivity observed being 0.1% for estradiol-17 alpha. In this system the monoclonal antib...
متن کاملQuantification of Human Chorionic Gonadotropin by Bovine Serum Albumin Nanoparticles
Background and Aims: Some nanoparticles can be used in immunoassays to increase sensitivity. This study aimed to evaluate a novel nano-immunoassay based on bovine serum albumin nanoparticles (BSA NPs). Materials and methods: At first, the nanostructure was synthesized, and then applied as a tag in the nano-immunoassay. Then the concentration of β-subunit of human chorionic gonadotropin ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 60 3 شماره
صفحات -
تاریخ انتشار 2014