Intracardiac pressure-sound correlates of echographic aortic valve closure.

نویسندگان

  • S Hirschfeld
  • J Liebman
  • G Borkat
  • C Bormuth
چکیده

Echographic aortic valve closure was compared to the dicrotic notch of the aortic pressure and intracardiac A2 to define the exact temporal relationship of the echographic, pressure, and sound parameters of aortic valve closure. Sixteen children, ages 3--20 years, were evaluated by simultaneous aortic valve echograms, micromanometric aortic root pressure tracings, and intracardiac phonocardiograms recorded at paper speeds of 200 mm/sec. Our observations demonstrated that echographic coaptation of the aortic valve leaflets coincides with the trough of the aortic pressure incisura and the onset of A2. The data suggest that A2 is a result of valve closure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemodynamic correlates of the normal aortic valve echogram. A study of sound, flow, and motion.

The aortic valve echogram was recorded in open chest dogs simultaneously with aortic flow, acceleration of flow, aortic and left ventricular pressures, and intracardiac phonocardiograms. Comparison of echographic with hemodynamic data showed the following: The aortic valve started its opening with the onset of flow, at the same point that left ventricular pressure exceeded aortic pressure. Comp...

متن کامل

The aortic closure sound in pure aortic insufficiency.

The second sound in aortic insufficiency has been described as accentuated, normal, or moderately diminished. A study of intracardiac phonocardiograms was performed to evaluate its intensity and to eliminate extracardiac factors. Pressure and intracardiac sound measurements were made in 28 patients undergoing diagnostic cardiac catheterization. Recordings were obtained above the aortic valve an...

متن کامل

Sound pressure correlates of the Austin Flint murmur. An intracardiac sound study.

Mitral valve motion and pressure correlates of the Austin Flint murmur (AFM) were investigated in nine patients with aortic regurgitation using high fidelity catheter tip micromanometers and the mitral valve echocardiogram (MVE). External phonocardiography demonstrated a mid-diastolic murmur (MDM) in eight subjects and a presystolic murmur (PSM) in five. Maximum intensity of both AFM components...

متن کامل

Sound-pressure correlates of the aortic ejection sound. An intracardiac sound study.

The sound-pressure correlates of the aortic ejection sound (AES) were studied in six patients without aortic valve disease (group 1) and in nine patients with valvular aortic stenosis (group 2) during diagnostic left heart catheterization. Aortic root sound and pressure events were recorded by a catheter-tip micromanometer simultaneously with the external phonocardiogram, indirect carotid pulse...

متن کامل

Additional Pulmonary Valve Closure Caused by the Catheter and Demonstrated by the Intracardiac Phonocardiogram.

Simultaneous recording of intracardiac pressures and heart sounds has been made possible by the introduction of a high-frequency micromanometer developed by Soulie et al. (1954). Using this technique Soulie et al. (1961) have reported their findings in congenital and acquired heart disease. Analysing the second heart sound in recordings from the pulmonary artery and right ventricle in 11 cases ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 55 4  شماره 

صفحات  -

تاریخ انتشار 1977