SU-E-T-506: Dosimetric Study for Shallow-Seated Tumor Using Passive/active Scanning Proton Beam.

نویسندگان

  • C Toramatsu
  • T Matsuura
  • H Nihongi
  • S Takao
  • N Miyamoto
  • S Shimizu
  • R Kinoshita
  • K Umegaki
  • H Shirato
چکیده

PURPOSE To investigate the possibility of using a single spot scanning proton beam to treat superficial lesions. METHODS A cylindrical phantom with a simulated superficial target (it seated 0.5-4cm depth from the surface, volume: 270cm3 ) was created in Eclipse treatment planning system. Three proton plans were generated: (a) a single AP uniform scanning beam with aperture and range compensator; (b) a single AP spot scanning beam with a pre-absorber. The location and thickness of the pre-absorber were calculated using Geant4 to Monte Carlo code to make use of the available spot scanning beams to get a conformal plan. (c) a five-beam spot scanning beam plan using multi-field optimization. The prescription is 54 cobalt grey equivalent (CGE) which covers 95% of the target. The target coverage, lateral penumbra at 2 and 4cm depth in water, the doses to normal tissue (phantom-target) and skin (2mm from the surface) were evaluated and compared for three plans. RESULTS The mean doses to the target are comparable within 2.4% for all three plans. The conformity indices (at 95%) are 1.36, 1.04 and 0.98 for plan (a), (b) and (c) respectively. The lateral penumbra (80% to 20%) for plan (a), (b) are both 0.73 cm, while it is 3.75 cm for plan (c). The skin dose which received more than 40 (CGE) from plan (a) is 10% higher than that of other two plans. Plan (c) has 70% higher mean doses to normal tissue than that of plan (a) and (b). CONCLUSIONS Each plan provides good coverage of target. And in this study, it showed that, with a properly designed pre-absorber, it is possible to use a single spot scanning beam to treat superficial lesion. The plan provides good target coverage and maintains normal tissue sparing in the mean time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of tumor motion influence on applied dose distribution in conventional proton therapy vs. IMPT a 4D Monte Carlo simulation study

Background: in radiation treatment of moving targets located in thorax region of patient body, the delivered dose does not match with the planned treatment, resulting in some over and under dosage in the tumor volume, as a function of motion magnitude and frequency. Several efforts have been done to investigate the target motion effects on dose distribution in the target and surrounding normal ...

متن کامل

Effects of Defining Realistic Compositions of the Ocular Melanoma on Proton Therapy

Background: Recent studies in eye plaque brachytherapy have shown a considerable difference between the dosimetric results using water phantom and a model of human eye containing realistic materials. In spite of this fact, there is a lack of simulation studies based on such a model in proton therapy literatures. In the presented work, the effect of utilizing an eye model with ocular media on pr...

متن کامل

طراحی و بهینه‌سازی طیف نوترونی برای درمان تومورهای عمیق مغزی به روش BNCT با کاهش آسیب رسیده به پوست

Boron neutron capture therapy (BNCT) is an effective method for treatment of deep seated brain tumors. This method consists of two stages: injection of boron compound in the patient body, and then irradiation of the region tumors with the neutron beam. It allows for delivery of high linear energy transfer (LET) radiation (particles 4He and 7Li nuclei) to tumors at the cellular level whilst avoi...

متن کامل

Validation of dosimetric field matching accuracy from proton therapy using a robotic patient positioning system

Large area, shallow fields are well suited to proton therapy. However, due to beam production limitations, such volumes typically require multiple matched fields. This is problematic due to the relatively narrow beam penumbra at shallow depths compared to electron and photon beams. Therefore, highly accurate dose planning and delivery is required. As the dose delivery includes shifting the pati...

متن کامل

Medical Equipment and Systems

In January 2014, the Nagoya Proton Th erapy Center became the fi rst clinic in Japan to treat patients using proton spot scanning. Th e new system operates alongside two existing treatment rooms that started treating patients in February 2013 and use a passive scattering system. Th is means that the Nagoya Proton Th erapy Center now has three treatment rooms, two with rotating gantries and one ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part18  شماره 

صفحات  -

تاریخ انتشار 2012