Diagnostic usefulness of an amino acid tracer, α-[N-methyl-11C]-methylaminoisobutyric acid (11C-MeAIB), in the PET diagnosis of chest malignancies

نویسندگان

  • Ryuichi Nishii
  • Tatsuya Higashi
  • Shinya Kagawa
  • Yoshihiko Kishibe
  • Masaaki Takahashi
  • Hiroshi Yamauchi
  • Hideki Motoyama
  • Kenzo Kawakami
  • Takashi Nakaoku
  • Jun Nohara
  • Misato Okamura
  • Toshiki Watanabe
  • Koichi Nakatani
  • Shigeki Nagamachi
  • Shozo Tamura
  • Keiichi Kawai
  • Masato Kobayashi
چکیده

OBJECTIVES Although positron emission tomography (PET) using [(18)F]-fluoro-2-deoxy-D-glucose ((18)F-FDG) is established as one of the first-choice imaging modalities in the diagnosis of chest malignancies, there are several problems to solve in clinical practice, such as false positive uptake in inflammatory diseases. The aim of this study was to evaluate the clinical usefulness of an amino acid tracer, α-[N-methyl-(11)C]-methylaminoisobutyric acid ((11)C-MeAIB), in the diagnosis of chest malignancies, in combination with (18)F-FDG. SETTING Fifty-nine cases (57 patients, 66 ± 12 years old) who consulted to our institution for the wish to receive differential diagnosis of chest diseases were included. Purpose of the studies were as follows: differential diagnosis of newly developed lung nodules, n = 22; newly developed mediastinal lesions, n = 20; and both, n = 17 (including lung cancer: n = 19, lymphoma: n = 1, other cancers: n = 2, sarcoidosis: n = 15, non-specific inflammation: n = 18, other inflammatory: n = 4, respectively). Whole-body static PET or PET/CT scan was performed 20 and 50 min after the IV injection of (11)C-MeAIB and (18)F-FDG, respectively. RESULTS (11)C-MeAIB uptake of malignant and benign lesions was statistically different both in pulmonary nodules (p < 0.005) and in mediastinal lesions (p < 0.0005). In visual differential diagnosis, (11)C-MeAIB showed higher results (specificity: 73 %, accuracy: 81 %), compared to those in (18)F-FDG (60, 73 %, respectively). In cases of sarcoidosis, (11)C-MeAIB showed higher specificity (80 %) with lower uptake (1.8 ± 0.7) in contrast to the lower specificity (60 %) with higher uptake of (18)F-FDG (7.3 ± 4.5). CONCLUSIONS (11)C-MeAIB PET/CT was useful in the differential diagnosis of pulmonary and mediastinal mass lesions found on CT. (11)C-MeAIB PET or PET/CT showed higher specificity than that of (18)F-FDG PET/CT in differentiating between benign and malignant disease. Our data suggest that the combination of (18)F-FDG and (11)C-MeAIB may improve the evaluation of chest lesions, when CT and (18)F-FDG PET/CT are equivocal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Discrepancy between radiological and histological findings in ganglioglioma of the optic chasm: Case report

BACKGROUND Gangliogliomas involving the optic nerve or chiasm are extremely rare tumors, which can be confused radiologically with other neoplasms. α-[N-methyl-11C]-methylaminoisobutyric acid (11C-MeAIB) is a new artificial amino acid positron emission tomography (PET) tracer, which is metabolically more stable in vivo and may be more specific for tumors than 11C-methionine. However, the utilit...

متن کامل

Diagnosis of Brain Tumors Using Amino Acid Transport PET Imaging With 18F- Fluciclovine: A Comparison Study With L-Methyl-11C-Methionine PET Imaging

Objective(s): 18F-fluciclovine (trans-1-amino-3-[18F] fluorocyclobutanecarboxylic acid, [FACBC]) is an artificial amino acid radiotracer used for positron emission tomography (PET) studies, which is metabolically stable in vivo and has a long half-life. It has already been shown that FACBC-PET is useful for glioma imaging. However, there have been no reports evaluating the efficiency of FACBC-P...

متن کامل

Whole-Body Distribution of Donepezil as an Acetylcholinesterase Inhibitor after Oral Administration in Normal Human Subjects: A 11C-donepezil PET Study

Objective(s): It is difficult to investigate the whole-body distribution of an orally administered drug by means of positron emission tomography (PET), owing to the short physical half-life of radionuclides, especially when 11C-labeled compounds are tested. Therefore, we aimed to examine the whole-body distribution of donepezil (DNP) as an acetylcholinesterase inhibitor by means of 11C-DNP PET ...

متن کامل

Amino acid transport system - A substrate predicts the therapeutic effects of particle radiotherapy

L-[methyl-11C]Methionine (11C-Met) is useful for estimating the therapeutic efficacy of particle radiotherapy at early stages of the treatment. Given the short half-life of 11C, the development of longer-lived 18F- and 123I-labeled probes that afford diagnostic information similar to 11C-Met, are being sought. Tumor uptake of 11C-Met is involved in many cellular functions such as amino acid tra...

متن کامل

Radiosynthesis of 11C-phenytoin Using a DEGDEE Solvent for Clinical PET Studies

Objective(s): Phenytoin is an antiepileptic drug that is used worldwide. The whole-body pharmacokinetics of this drug have been extensively studied using 11C-phenytoin in small animals. However, because of the limited production amounts that are presently available, clinical 11C-phenytoin PET studies to examine the pharmacokinetics of phenytoin in humans have not yet been performed. We aimed to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 27  شماره 

صفحات  -

تاریخ انتشار 2013