EMG contamination of EEG: spectral and topographical characteristics.
نویسندگان
چکیده
OBJECTIVE Electromyogram (EMG) contamination is often a problem in electroencephalogram (EEG) recording, particularly, for those applications such as EEG-based brain-computer interfaces that rely on automated measurements of EEG features. As an essential prelude to developing methods for recognizing and eliminating EMG contamination of EEG, this study defines the spectral and topographical characteristics of frontalis and temporalis muscle EMG over the entire scalp. It describes both average data and the range of individual differences. METHODS In 25 healthy adults, signals from 64 scalp and 4 facial locations were recorded during relaxation and during defined (15, 30, or 70% of maximum) contractions of frontalis or temporalis muscles. RESULTS In the average data, EMG had a broad frequency distribution from 0 to >200 Hz. Amplitude was greatest at 20-30 Hz frontally and 40-80 Hz temporally. Temporalis spectra also showed a smaller peak around 20 Hz. These spectral components attenuated and broadened centrally. Even with weak (15%) contraction, EMG was detectable (P<0.001) near the vertex at frequencies >12 Hz in the average data and >8 Hz in some individuals. CONCLUSIONS Frontalis or temporalis muscle EMG recorded from the scalp has spectral and topographical features that vary substantially across individuals. EMG spectra often have peaks in the beta frequency range that resemble EEG beta peaks. SIGNIFICANCE While EMG contamination is greatest at the periphery of the scalp near the active muscles, even weak contractions can produce EMG that obscures or mimics EEG alpha, mu, or beta rhythms over the entire scalp. Recognition and elimination of this contamination is likely to require recording from an appropriate set of peripheral scalp locations.
منابع مشابه
Brain-computer interface (BCI) operation: signal and noise during early training sessions.
OBJECTIVE People can learn to control mu (8-12 Hz) or beta (18-25 Hz) rhythm amplitude in the electroencephalogram (EEG) recorded over sensorimotor cortex and use it to move a cursor to a target on a video screen. The recorded signal may also contain electromyogram (EMG) and other non-EEG artifacts. This study examines the presence and characteristics of EMG contamination during new users' init...
متن کاملSpatial spectra of scalp EEG and EMG from awake humans.
OBJECTIVE Evaluate spectral scaling properties of scalp electroencephalogram (EEG) and electromyogram (EMG), optimal spacing of electrodes, and strategies for mitigating EMG. METHODS EEG was recorded referentially from 9 subjects with a 64 channel linear array (electrodes 3mm apart) placed parasagittally or transversely on forehead or occiput, at rest with eyes open or closed, or with deliber...
متن کاملEMG-based wrist gesture recognition using a convolutional neural network
Background: Deep learning has revolutionized artificial intelligence and has transformed many fields. It allows processing high-dimensional data (such as signals or images) without the need for feature engineering. The aim of this research is to develop a deep learning-based system to decode motor intent from electromyogram (EMG) signals. Methods: A myoelectric system based on convolutional ne...
متن کاملFacial muscle activity, Response Entropy, and State Entropy indices during noxious stimuli in propofol–nitrous oxide or propofol–nitrous oxide–remifentanil anaesthesia without neuromuscular block
BACKGROUND Entropy is an anaesthetic EEG monitoring method, calculating two numerical parameters: State Entropy (SE, range 0-91) and Response Entropy (RE, range 0-100). Low Entropy numbers indicate unconsciousness. SE uses the frequency range 0.8-32 Hz, representing predominantly the EEG activity. RE is calculated at 0.8-47 Hz, consisting of both EEG and facial EMG. RE-SE difference (RE-SE) can...
متن کاملEffects of concurrent visual tasks on cortico-muscular synchronization in humans.
To study the effects of external visual stimulation on motor cortex-muscle synchronization, coherence between electroencephalography (EEG) and electromyography (EMG) was measured in normal subjects under Before, Task (visual task: Ignore or Count, or arithmetic task) and After conditions. The control (Before and After) conditions required the subject to maintain first dorsal interosseous muscle...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology
دوره 114 9 شماره
صفحات -
تاریخ انتشار 2003