A capacitance pressure sensor using a phase-locked loop.

نویسندگان

  • A Patel
  • M Kothari
  • J G Webster
  • W J Tompkins
  • J J Wertsch
چکیده

We are using a Hercules (model #F4-4R, 100 psi) pressure sensor to measure the pressure between the foot and shoe. An interface circuit converts the capacitance change into voltage. Over the pressure range from 0 to 1300 kPa, the capacitance changes from 275 to 580 pF. A 555 timer circuit converts the capacitance into a frequency range from 30 to 63 kHz. A phase-locked loop (PLL) converts this frequency to voltage from 0 to 5 V, which is then filtered using a first-order, low-pass filter, having a corner frequency of 20 Hz to reduce the ripple to 10 mV. The sensor's hysteresis is about 8 percent at 40 degrees Celsius (C) and 12 percent at 20 degrees C. The sensor has a maximal nonlinearity of 8 percent and a worst-case nonrepeatibility of 7 percent. Its temperature coefficient is -0.147 percent per degree C. Its spatial sensitivity decreases nonlinearly from 1 to 0.17 from the center towards the periphery. The sensitivity of the system is 2.77 mV/kPa and the temperature drift is +0.53 percent per degree C. We monitor the pressure at 7 locations under each foot (the rear and the front heel, great toe, and 4 of the 5 metatarsal heads). A portable data-acquisition system permits continuous monitoring for 7 minutes. Test results for pressure distribution for normal walk and run are presented. Results are useful when studying normal and abnormal gait, and for possibly providing feedback (sensory substitution) to diabetic patients with insensate feet in order to help them dynamically adjust pressure distribution under their feet.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Utilization of Novel Bandpass Sigma-delta Modulator for Capacitance Pressure Sensor Signal Processing

The paper deals with a novel approach to processing of pressure sensor signals. A bandpass sigma-delta modulator is used for this purpose. This technique is relatively new and it is not used widely, because this kind of modulator is usually utilized for wireless and video applications. Since the bandpass sigma-delta modulator works within its defined band it is resistant to offsets of its subci...

متن کامل

Modeling of capacitance and sensitivity of a MEMS pressure sensor

In this paper modeling of capacitance and sensitivity for MEMS capacitive pressure sensor is presented. In capacitive sensor the sensitivity is proportional to deflection and capacitance changes versus pressure. Therefore first the diaphragm displacement, capacitance and sensitivity of sensor with square diaphragm have been modeled and then simulated using finite element method (FEM).  It can b...

متن کامل

Dual Phase Detector Based Delay Locked Loop for High Speed Applications

In this paper a new architecture for delay locked loops will be presented.  One of problems in phase-frequency detectors (PFD) is static phase offset or reset path delay. The proposed structure decreases the jitter resulted from PFD by switching two PFDs. In this new architecture, a conventional PFD is used before locking of DLL to decrease the amount of phase difference between input and outpu...

متن کامل

Accurate Model of Capacitance for MEMS Sensors using Corrugated Diaphragm with Residual Stress

In this paper we present a new model for calculating the capacitance of MEMS sensor with corrugated diaphragm. In this work the effect of residual stress is considered on deflection of diaphragm and capacitance of sensor. First, a new analytical analyzes have been carried out to derive mathematic expressions for central deflection of corrugated diaphragm and its relationship with residual stres...

متن کامل

High Speed Delay-Locked Loop for Multiple Clock Phase Generation

In this paper, a high speed delay-locked loop (DLL) architecture ispresented which can be employed in high frequency applications. In order to design the new architecture, a new mixed structure is presented for phase detector (PD) and charge pump (CP) which canbe triggered by double edges of the input signals. In addition, the blind zone is removed due to the elimination of reset signal. Theref...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of rehabilitation research and development

دوره 26 2  شماره 

صفحات  -

تاریخ انتشار 1989