Optimized method for measuring aspartate aminotransferase activity with the CentrifiChem Analyzer, with automatic preincubation of serum.

نویسندگان

  • G Ertingshausen
  • L Amsellem-Winzelberg
  • J F Richert
  • R Davids
چکیده

We propose a routine method for the mechanized measurement of aspartate aminotransferase with the CentrifiChem Analyzer, which is based on the recommendations of both the International Federation of Clinical Chemistry and the Société Française de Biologie Clinique. A modification of the CentrifiChem pipettor permits simultaneous pipetting of two reagents, thus achieving automatic preincubation of the serum in the transfer disk. Owing to the fixed reagent volumes dispensed by the pipettor, preincubation conditions had to be modified, but the recommendations for the final reagent concentrations in the assay cuvet were observed. The totally automated method correlates very well with one involving manual pipetting to reproduce the detailed step-by-step recommendations of the International Federation of Clinical Chemistry. Intra-assay precision ranged from 3.4 to 4.9% and interassay precision from 1.7 to 7.5%. We assayed 135 sera and obtained a correlation coefficient of 0.996 (a = 1.025, b = 0.08).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Changes in the Level of Mitochondrial and Cytosolic Aspartate Aminotransferase Activities in Aluminium Intoxified Rat

The activity of aspartate aminotransferase (AST) in human serum has been widely determined as a diagnostic aid in liver disease. In this study, the effect of aluminium on AST isoenzymes in relation to aluminium intoxified patients has been investigated. Using gel filtration chromatography technique with Sephacryl S-300, mitochondrial aminotransferase (m-AST) and cytosolic aminotransferase (c-AS...

متن کامل

Preincubation of serum aspartate aminotransferase with pyridoxal 5'-phosphate in the SMAC: comparison with revised DuPont aca method and recommended IFCC method.

The method for continuous-flow assay of aspartate aminotransferase with the Technicon SMAC was modified to include preincubation of the serum enzyme with pyridoxal 5'-phosphate, to be consistent with the recommendations of IFCC and the Standards Committee of AACC. Preliminary estimates of the imprecision of the modified method on SMAC gave day-to-day standard deviations of 5.3 U/L at mean of 48...

متن کامل

Increased aspartate aminotransferase activity of serum after in vitro supplementation with pyridoxal phosphate.

We examined the effect of pyridoxal phosphate supplementation on the apparent aspartate aminotransferase (EC 2.6.1.1.) activity of human serum. Supplementation by 25 mol/liter effected an average increase of 16% in the results for kinetic assay. The increase was not the result of increased enzymatic or nonenzymatic blanks, and, within a small range, sample dilution had no significant effect. Pa...

متن کامل

Unexplained High Activity of Aspartate Aminotransferase in an Asymptomatic Pediatric Patient

Elevated enzyme activities in plasma may at times be attributed to the presence of macro-enzymes. The macro-enzymes are often serum enzymes in complex with immunoglobulins, resulting in a greater molecular mass that cannot be filtered by renal glomeruli and are, hence, retained in the plasma. The aspartate aminotransferase (AST) can exist as a macro-enzyme, although it has been rarely reported....

متن کامل

Kinetic determination of serum sorbitol dehydrogenase activity with a centrifugal analyzer.

We describe a mechanized method for centrifugal analyzer determination of sorbitol dehydrogenase in serum, based on conversion of D-fructose to sorbitol with simultaneous oxidation of NADH, in triethanolamine buffer at pH 7.4 and 30 degrees C. The standard curve for this assay is linear to 200 U of activity per liter of serum. The mean within-run precision (CV) of the assay is 0.8%. Results cor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 24 7  شماره 

صفحات  -

تاریخ انتشار 1978