Retrieval analysis of failed constrained acetabular liners.
نویسندگان
چکیده
Despite the large loads placed upon constrained acetabular liners, little is known of their mechanical performance. We analyzed retrieved liners to determine wear and other damage modes and assess associations between types and severity of damage and clinical, radiographic, and implant variables. Outer rim impingement frequency and severity were higher than that for the inner rim. The 20 degrees elevation was most frequently affected by impingement. Inner rim impingement was more frequent with small heads. Outer bearing surface wear scores were higher than inner bearing scores. Liners removed for infection or stem failure had similar damage compared with other groups, demonstrating the complex relationship of impingement and wear with clinical performance. No association was found between liner damage and clinical and radiographic variables.
منابع مشابه
Early failure mechanisms of constrained tripolar acetabular sockets used in revision total hip arthroplasty.
Fifty-eight patients received an Osteonics constrained acetabular implant for recurrent instability (46), girdlestone reimplant (8), correction of leg lengthening (3), and periprosthetic fracture (1). The constrained liner was inserted into a cementless shell (49), cemented into a pre-existing cementless shell (6), cemented into a cage (2), and cemented directly into the acetabular bone (1). Ei...
متن کاملRetrieval analysis of Harris-Galante I and II acetabular liners in situ for more than 10 years
BACKGROUND AND PURPOSE There have been few reports documenting the wear and oxidation performance of the polyethylene bearing surface of HGPI and HGPII THA devices. We evaluated retrieved HGPI and HGPII acetabular liners that had been in situ for more than 10 years and determined whether there was a relationship between clinical and radiographic factors, surface damage, wear, and oxidation. M...
متن کاملConstrained acetabular liners in hip revision surgery. A low-cost solution for senile patients.
The objective of this study was to analyze the results of a cemented polyethylene model that captures the hip prosthetic head. In a retrospective study we reviewed 36 cemented constrained acetabular liners implanted in patients older than 75 years (mean 83, SD : 4.4), of which 30 patients were aged 80-90 years and 26 were women. The average period of follow-up of our patients was 25.4 months (1...
متن کاملRetrieval Analysis of Sequentially Annealed Highly Crosslinked Polyethylene Used in Total Hip Arthroplasty
BACKGROUND First-generation annealed and second-generation sequentially annealed, highly crosslinked polyethylenes (HXLPEs) have documented reduced clinical wear rates in their first decade of clinical use compared with conventional gamma inert-sterilized polyethylene. However, for both types of annealed HXLPE formulations, little is known about their reasons for revision, their in vivo oxidati...
متن کاملHighly cross-linked polyethylene acetabular liners retrieved four to five years after revision surgery: a report of two cases.
There is currently considerable interest in the use of highly cross-linked polyethylene (XLPE) acetabular liners for total hip arthroplasty (THA). In literature, only a single retrieval analysis of one type of XLPE liner implanted for greater than four years exists. The purpose of the present report is to quantify surface deviations in two XLPE liners implanted during revision THA and retrieved...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of arthroplasty
دوره 24 6 Suppl شماره
صفحات -
تاریخ انتشار 2009