An Evaluation of the Organ Dose Received by Cardiologists Arising From Angiography Examinations in Educational Hospital in Rasht

نویسندگان

  • Akram Shoshtary
  • Jalil Pirayesh Islamian
  • Mohsen Asadinezhad
  • Alireza Sadremomtaz
چکیده

Interventional procedures, cine acquisitions and operation of fluoroscopic equipment in high-dose fluoroscopic modes, involve long fluoroscopic times which can lead to high staff doses. Also, Coronary angiography (CA) procedures require the cardiologist and assisting personnel to remain close to the patient, which is the main source of scattered radiation. Thus, radiation exposure is a significant concern for radiation workers and it is important to measure the radiation doses received by personnel and evaluate the parameters concerning total radiation burden. In this research, we investigated radiation doses to 10 cardiologists performing 120 CA procedures. Using thermo luminescent dosimeters doses to the wrists, thyroid and eyes per procedure were measured. Based on the measured dose values, maximum doses to the Left wrist, Right wrist, thyroid and eyes of cardiologist were measured 241.45 µSv, 203.17 µSv, 78.21 µSv and 44.58 µSv, respectively. The results of this study indicate that distance from the source, use of protective equipment's, procedure complexity, equipment performance, and cardiologist experience are the principal exposure-determining variables. It can be conclude that if adequate radiation protection approaches have been implemented, occupational dose levels to cardiologists would be within the regulated acceptable dose limits.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Maximum Patient Skin Dose Arising from Interventional Cardiology Using Thermoluminescence Dosimeter in Mashhad, Iran

Introduction The increasing practice of interventional fluoroscopy in diagnosis and treatment of cardiovascular disease has risen attention to improve radiation protection of patients and cardiologists in these relatively high dose techniques. Therefore, nowadays there is an emphasis on the measurement of radiation dose received by patients and cardiologists arising from the relevant procedures...

متن کامل

Evaluation of Organ and Effective Doses to Patients Arising From Some Common X-Ray Examinations by PCXMC Program in Sabzevar, Iran

Introduction The purpose of this study was to estimate organ and effective doses in patients undergoing some common X-ray examinations in Sabzevar, Iran. The effective dose is one of the best parameters for describing the amount of radiation dose received by a patient undergoing any diagnostic X-ray examination. The public dose from X-ray examinations depends on various factors, and its contrib...

متن کامل

Evaluation of cancer risk of the patients undergoing coronary angiography in Yazd, Iran

Background: Coronary angiography is a commonly performed diagnostic procedure with life saving benefits for the patient. However, this procedure involves relatively high radiation dose. The purpose of this study was to determine the average effective dose of patients undergoing coronary angiography and to estimate the associated radiation risk in terms of fatal malignancy. Materials an...

متن کامل

Patient dose values during interventional cardiology examinations in Yazd hospital, Iran

Background: The number of interventional cardiology (IC) procedures has increased rapidly. coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) are now widely performed as a matter of routine, and they are considered safe procedures for experienced cardiologists. However, it is also known that these procedures are associated with high radiation doses due to long f...

متن کامل

Organ and effective dose arising from conventional diagnostic X-ray examinations by Monte Carlo simulation (MCNP-4C Code)

 ABSTRACTBackground: Monte Carlo simulation has been used by many researchers to calculate organ and effective dose of patients arising from conventional X-ray examinations. In this study the radiation transport code, MCNP-4C, has been used to perform Monte Carlo simulations to estimate radiation dose delivered to different organs in conventional X-ray examinations.Material and Methods: In this...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2015