Determination of the Temperature Change by Means of an Outcoming Signal of Electric Resistance in an Isoperibolic Calorimetric Cell. Obtainment of Heat Solution
نویسندگان
چکیده
An isoperibolic calorimetric cell is built with glass surrounded by plastic insulation. The cell has a lid on which a thermistor thermometer, an electric resistance to provide the cell with definite quantities of electric work and a container for a glass ampoule, are placed. For measuring the thermal changes, an NTC thermistor, which provides an electric resistance signal that varies with temperature, is used. Calibration curves of the thermistor and of the stabilization of the system signal in thermal equilibrium are shown, which enable the observation of a good insulation. The calorific capacity of the system with water, with a value of 206.7 ± 0.7 J °C is determined; the solution enthalpy for propanolwater and KCl-water systems is obtained, which shows the behavior of the cell before exothermic and endothermic effects, respectively.
منابع مشابه
Determination of solution temperature in an ex-service Ni-based turbine blade
It is well-known that the harsh operational conditions of turbine blades lead to a gradual change in the microstructure of underlying Ni-based superalloy of blades. According to this, a rejuvenation process should be conducted on turbine blades superalloys to recover their microstructures. The first and main step of rejuvenation process is the determination of appropriate solution condition in ...
متن کاملDETERIORATION OF PITTING CORROSION OF 316 STAINLESS STEEL BY SENSITIZATION HEAT TREATMENT
In this research pitting Corrosion of a sensitized 316 stainless steel was investigated employing potentiodynamic, potentiostatic techniques. Sensitization process was carried out on as-received alloy by submitting the specimen in electric furnace set at 650°Cfor five hours and then the specimen was quenched 25°C water. Potentiodynamic polarization of as received and sensitized specimens in 1M ...
متن کاملIsoperibolic Calorimetric Measurements of the Fleischmann-Pons Effect
Important advantages exist for selecting a Dewar type isoperibolic calorimeter for measurements of anomalous excess enthalpy produced by the Fleischmann-Pons Effect (FPE). These advantages include a wide dynamic range for both the cell temperature and cell input power, direct visual observations inside the cell during calorimetric experiments, relative low cost, selfpurification of the system, ...
متن کاملDetermination of Bio-Oxidation Energy Released by Thermophiles in Secondary and Mixed Bio-Solids
Reaction constants and heat release during thermophilic aerobic digestion of typical secondary and mixed sludges were determined. Maximum reaction constant, determined by measuring the amounts of biodegradable volatile suspended solids (bVSS) removed, occurred in the temperature range of 55-60 ºC. Measurement of heat releases were carried out, at the same range, by the aid of a temperature ...
متن کاملEvaluation of Heat Treatments and Their Effects on the Corrosion Behavior of TiAlON Coatings Prepared by Cathodic Arc Evaporation on D3 Tool Steel
A series of TiAlON coatings were synthesized in a gaseous mixture of argon, nitrogen and oxygen by cathodic arc evaporation method using a Ti–Al mosaic target. Oxidation of coatings was carried out by heating the coated samples at the temperatures of 500, 600, 700, and 800°C for 1 h in air atmosphere. It was found that heat treatment changed the microstructure and composition of the coating. Th...
متن کامل