The application of the ventilation equations to cleanrooms – Part 2: Decay of contamination

نویسندگان

  • W Whyte
  • S Ward
  • WM Whyte
  • T Eaton
چکیده

This article is the second of a three-part series that investigates the application of the ventilation equations to designing and testing cleanrooms. This part is concerned with the decay equation. The recovery test, described in ISO 14644-3 (2005) is discussed, and improvements recommended. The application of the decay equation to the ‘clean up’ requirement given in the EU GGMP (2008) is also discussed. Finally, a method is considered that calculates the time needed for airborne contamination in cleanroom areas to decay to acceptable concentrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Decay of airborne contamination and ventilation effectiveness of cleanrooms

This article reports an investigation into the ability of the air supply in non-unidirectional cleanrooms to aid recovery from episodes of airborne contamination, and minimise airborne contamination at important locations. The ISO 14644-3 (2005) recovery test, which measures the rate of decay of test particles, was assessed and a reinterpretation of the test results suggested. This allowed air ...

متن کامل

Calculation of airborne cleanliness and air supply rate for non-unidirectional airflow cleanrooms

When designing a cleanroom to achieve a required airborne cleanliness standard or grade, such as specified in ISO 1464411 or the European Union Guidelines to Good Manufacturing Practice (EU GGMP)2, designers have difficulties deciding how much filtered air should be supplied to the cleanroom to achieve the correct airborne cleanliness requirement. Currently, this decision is based on experience...

متن کامل

Equations for predicting airborne cleanliness in non-unidirectional airflow cleanrooms

When designing a cleanroom to achieve a required airborne cleanliness class or grade, such as specified in the International Organization for Standardization (ISO) 14644-11, or the European Union Guidelines to Good Manufacturing Practice (EU GGMP)2, designers have a problem in deciding how much filtered air should be supplied to the cleanroom. Currently, this is not normally calculated but base...

متن کامل

ارزیابی پارامترهای عملکردی در فیلترهای هپا در یک صنعت دارویی(مطالعه موردی1394)

Abstract: Background and aims: Nowadays, cleanrooms have become impartible parts of an industry with sensitive products. Sources of contamination in cleanrooms are impaired performance and quality sensitive products in the cleanrooms .The aim of this study was to evaluate the efficiency of HEPA filter and check the concentration and number of airborne particles in cleanrooms for pharmaceutic...

متن کامل

Optimizing naturally driven air flow in a vertical pipe by changing the intensity and location of the wall heat flux

Heat transfer from the internal surfaces of a vertical pipe to the adjacent air gives rise to the air flow establishment within the pipe. With the aim of optimizing the convective air flow rate in a vertical pipe, the details of the flow and thermal fields were investigated in the present study. Conservation equations of mass, momentum, and energy were solved numerically using simple implicit f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014