In vivo evaluation of a reverse thermosensitive polymer for ureteroscopy with laser lithotripsy: porcine model.

نویسندگان

  • Jonathan M Mobley
  • Goutham Vemana
  • Marshall Strother
  • Robert Sherburne Figenshau
  • Joel M Vetter
  • Jeffrey Larson
  • Brian M Benway
چکیده

PURPOSE To evaluate the effects of a reverse thermosensitive polymer during ureteroscopy with laser lithotripsy in an in vivo porcine model. MATERIALS AND METHODS Six pigs underwent general anesthesia followed by bilateral ureteroscopy with laser lithotripsy of stone phantoms while measuring intrapelvic renal pressures through bilateral nephrostomy tubes. The procedures were performed in one ureter with the reverse thermosensitive polymer and in the contralateral, control ureter without the reverse thermosensitive polymer. Stone migration lengths, operative times, laser times, laser energy usage, intrapelvic pressures, and postnecropsy histologic examinations of the ureters were compared between the two groups. RESULTS Bilateral ureteroscopy with lithotripsy was successfully performed in five of six pigs. In one pig, only the unilateral control was performed, because the ureter was too narrow to complete the contralateral side. The mean laser time was 12.8 minutes shorter with the use of the reverse thermosensitive polymer group than in the controls (P=0.021). The procedure time, laser energy usage, and retropulsion length was shorter in the reverse thermosensitive polymer group, but did not reach significance. Between the two groups, there was no difference in mean renal pelvic pressures, peak renal pelvic pressures, or postprocedure histologic examinations of the ureters. CONCLUSIONS The use of a reverse thermosensitive polymer during ureteroscopy with lithotripsy may have greater advantages beyond preventing stone retropulsion. Here, the use of a reverse thermosensitive polymer during ureteroscopy with lithotripsy resulted in a significant decrease in laser times. Further clinical investigations could further delineate the advantages of using a reverse thermosensitive polymer during intracorporeal lithotripsy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of the Moses Technology to Improve Holmium Laser Lithotripsy Outcomes: A Preclinical Study

OBJECTIVE To evaluate in vitro and in vivo effects of Moses technology in Holmium laser and to compare it with the Regular mode in terms of lithotripsy efficiency and laser-tissue interactions. METHODS The Lumenis® Pulse™ P120H holmium laser system together with Moses D/F/L fibers were used to compare the Regular mode with the Moses modes in stone retropulsion by using a high-speed camera, an...

متن کامل

Extracorporeal shockwave lithotripsy and intracorporeal lithotripsy for proximal ureteric calculi--a comparative assessment of efficacy and safety.

INTRODUCTION Extracorporeal shockwave lithotripsy (ESWL) is the treatment modality of choice of many urologists for proximal ureteric calculi. In this study, we compared the efficacy and safety of ESWL versus ureteroscopy with holmium laser lithotripsy for the treatment of this group of stones. MATERIALS AND METHODS Between May 1999 and October 2000, 50 patients had ESWL and another 51 patien...

متن کامل

Management of upper ureteral stones exceeding 15 mm in diameter: Shock wave lithotripsy versus semirigid ureteroscopy with holmium:yttrium–aluminum–garnet laser lithotripsy

OBJECTIVES We conducted a retrospective study to evaluate the efficacy and outcome of shock wave lithotripsy versus semirigid ureteroscopy in the management of the proximal ureteral stones of diameter exceeding 15 mm. METHODS During the 2009-2014 study period, 147 patients presenting with the proximal ureteral stones exceeding 15 mm in diameter were treated. Both shock wave lithotripsy and ur...

متن کامل

Preventing migration of stones during fragmentation with thermosensitive polymer.

PURPOSE To define a method of stabilizing stones during extracorporeal (SWL) and intracorporeal lithotripsy with a thermosensitive polymer. MATERIALS AND METHODS Using a thermosensitive polymer that is either a liquid or a gel, depending on the temperature, both calcium oxalate and plaster of Paris phantom stones were placed in the polymer gel or saline, and SWL was performed. Comparisons wer...

متن کامل

Intrarenal pressures generated during deployment of various antiretropulsion devices in an ex vivo porcine model.

INTRODUCTION Pressurized saline irrigation is commonly used during ureteroscopy, which can cause an increase in intrarenal pressure leading to postoperative pain, sepsis, and renal injury due to pyelovenous and pyelolymphatic backflow. To prevent retrograde stone migration during ureteroscopic lithotripsy, antiretropulsion devices can be deployed, which may or may not protect the kidney against...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endourology

دوره 28 5  شماره 

صفحات  -

تاریخ انتشار 2014