Initial experience with proximal anastomoses performed with a mechanical connector.

نویسندگان

  • Michael J Mack
  • Robert W Emery
  • Laura R Ley
  • Peter A Cole
  • Allie Leonard
  • James R Edgerton
  • Todd M Dewey
  • Mitchell J Magee
  • Thomas S Flavin
چکیده

BACKGROUND The Symmetry Bypass System Aortic Connector (St Jude Medical, Inc) is a novel device for the construction of sutureless proximal anastomoses. The connector allows attachment of saphenous vein grafts to the aorta without requiring aortic clamping. We report our initial clinical experience with this device. METHODS In a 2-month period from May to July 2001, a total of 139 consecutive proximal anastomoses were performed in 67 patients using the connector. All procedures were performed on a beating heart without cardiopulmonary bypass or any aortic clamping. Intraoperative variables and postoperative results were prospectively collected and retrospectively analyzed. RESULTS Of 139 consecutive proximal anastomoses 138 (99.3%) were successfully completed with the device. One anastomosis required suture revision because of misdeployment. Six anastomoses (4.3%) required an additional suture for leak. Predeployment problems included connector loading/preparation malfunction in 10 grafts (7.2%), five because of human error and five technical failure. There was no operative mortality, perioperative myocardial infarction, or stroke. Vessels bypassed included the circumflex system (n = 59), right coronary artery and branches (n = 48), diagonal branch (n = 26), and left anterior descending coronary artery (n = 6). At a mean follow-up of 7 months, survival was 94.1% and survival free of major adverse cardiac and cerebrovascular events (MACCE) was 88.1%. CONCLUSIONS Initial clinical experience with a sutureless proximal saphenous vein graft to aorta anastomosis performed with a mechanical connector demonstrates safety, reliability, and ease of use. Surmounting a brief learning curve improves the subtleties of device loading and deployment. Further benefits will be determined in an ongoing randomized study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal target international normalized ratio for patients with mechanical heart valves.

1. Katariya K, Yassin S, Tehrani HY, Lombardi P, Masroor S, Salerno TA. Initial experience with sutureless proximal anastomoses performed with a mechanical connector leading to clampless off-pump coronary artery bypass surgery. Ann Thorac Surg 2004;77:563–7. 2. Cavendish JJ, Penny WF, Madani MM, et al. Severe ostial saphenous vein graft disease leading to acute coronary syndromes following prox...

متن کامل

eComment: Aortic connectors in coronary artery surgery.

do not decrease embolic debris compared with conventional anastomoses in CABG. Eur J Cardiothorac Surg 2004;25:993–1000. w3x Bergsland J, Hol PK, Lingas PS, Lundblad R, Rein KA, Andersen R, Mork BE, Halvorsen S, Mujanovic E, Kabil E, Svennevig JL, Fosse E. Intraoperative and intermediate-term angiographic results of coronary artery bypass surgery with Symmetry proximal anastomotic device. J Tho...

متن کامل

First clinical results with a new mechanical connector for distal coronary artery anastomoses in CABG.

BACKGROUND Coronary anastomoses are currently primarily carried out with the use of running nonabsorbable sutures. Recently, a renewed interest has developed for facilitated mechanical anastomotic devices especially for minimal invasive techniques or limited access surgery. The initial experience with the first successful creation of mechanical vein-to-coronary artery anastomoses in humans is r...

متن کامل

The St Jude Medical symmetry aortic connector system for proximal vein graft anastomoses in coronary artery bypass grafting.

OBJECTIVES A new device designed to create proximal vein graft anastomoses to the aorta in coronary artery bypass grafting was recently developed by the St Jude Medical Anastomotic Technology Group (Minneapolis, Minn). This new anastomosis system consists of a nickel-titanium (nitinol) connector, an aortic cutter, and a delivery device. METHODS The loading of the vein on the aortic connector ...

متن کامل

Decreased intermediate term patency of automated proximal anastomoses evaluated by sequential ultrafast CT.

OBJECTIVE The Symmetrytrade mark aortic connector creates proximal anastomoses of saphenous vein grafts using a nitinol implant. The device avoids partial clamping and thus possibly reduces neurologic complications. To evaluate graft patency, a single surgeon randomised study was performed in our institution. METHODS Seventy-seven patients were randomised either to automated proximal anastomo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of thoracic surgery

دوره 75 6  شماره 

صفحات  -

تاریخ انتشار 2003