Genome Sequence of Legionella massiliensis, Isolated from a Cooling Tower Water Sample

نویسندگان

  • Isabelle Pagnier
  • Olivier Croce
  • Catherine Robert
  • Didier Raoult
  • Bernard La Scola
چکیده

We present the draft genome sequence of Legionella massiliensis strain LegA(T), recovered from a cooling tower water sample, using an amoebal coculture procedure. The strain described here is composed of 4,387,007 bp, with a G+C content of 41.19%, and its genome has 3,767 protein-coding genes and 60 predicted RNA genes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Isolation of Legionella pneumophila from Tehran Hospital Water Samples

Over a Period of three months (summer), 108 samples of water collected from four hospitals in Te-hran. They were taken from numerous potable and non-potable water, including main supply cis-terns, calorifiers, hot and cold tap water, shower, cooling tower and drain of air condition system. Culturing of concentrated and non-concentrated water samples on Buffered Charcoal Yeast Extract (BCYE) Aga...

متن کامل

Distribution of sequence-based types of legionella pneumophila serogroup 1 strains isolated from cooling towers, hot springs, and potable water systems in China.

Legionella pneumophila serogroup 1 causes Legionnaires' disease. Water systems contaminated with Legionella are the implicated sources of Legionnaires' disease. This study analyzed L. pneumophila serogroup 1 strains in China using sequence-based typing. Strains were isolated from cooling towers (n = 96), hot springs (n = 42), and potable water systems (n = 26). Isolates from cooling towers, hot...

متن کامل

Isolation of Legionella pneumophilia from cooling tower water by filtration.

Methods are described for detection of Legionella pneumophila in cooling tower water or other water sources by direct fluorescent-antibody staining. A procedure for isolation of Legionella bacteria from water samples by guinea pig inoculation is described. Two different serogroups of L. pneumophila were isolated repeatedly from one of the cooling towers.

متن کامل

Isolation of Legionella pneumophila from Tehran Hospital Water Samples

Over a Period of three months (summer), 108 samples of water collected from four hospitals in Tehran. They were taken from numerous potable and non-potable water, including main supply cisterns, calorifiers, hot and cold tap water, shower, cooling tower and drain of air condition system. Culturing of concentrated and non-concentrated water samples on Buffered Charcoal Yeast Extract (BCYE) Agar ...

متن کامل

Prevalence and Molecular Characteristics of Waterborne Pathogen Legionella in Industrial Cooling Tower Environments

Cooling towers are a source of Legionnaires' disease. It is important from a public health perspective to survey industrial cooling towers for the presence of Legionella. Prospective surveillance of the extent of Legionella pollution was conducted at factories in Shijiazhuang, China between March 2011 and September 2012. Overall, 35.7% of 255 industrial cooling tower water samples showed Legion...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2014