Efficacy and Safety of the WATCHMAN Left Atrial Appendage System for Stroke Prevention in Chinese Patients with Nonvalvular Atrial Fibrillation: A Single-center, Prospective, Observational Study

نویسندگان

  • Wei-Ping Huang
  • Yong-Hua Zhang
  • Lei He
  • Xi Su
  • Xin-Wei Yang
  • Zai-Xiong Guo
چکیده

BACKGROUND In patients with nonvalvular atrial fibrillation (NVAF), embolic stroke is thought to be associated with left atrial appendage (LAA) thrombi. The WATCHMAN LAA Occlusion Device has been shown to be noninferior to conventional oral anticoagulation with warfarin for stroke prevention in patients with NVAF. This study aimed to evaluate the procedural feasibility, safety and 12-month outcomes of the WATCHMAN LAA Occlusion Device in NVAF patients with high risk for stroke in China. METHODS The clinical data of 106 NVAF patients, who were consecutively underwent LAA closure with the WATCHMAN Device between April 2014 and May 2015, were collected. Patients were followed up at 1, 3, 6, and 12 months after discharge. A transesophageal echocardiograph was performed at 45 days after implantation and repeated in case of an unexpected event during the follow-up period. RESULTS This study included 106 NVAF patients with a mean age of 64.2 ± 8.6 years (ranging from 50 to 88 years), and the mean CHA2DS2-VASc score of all patients was 3.6 ± 1.6 (ranging from 2 to 9). Among those 106 NVAF patients, 100 (94.3%) patients were implanted with the device successfully. The procedural success rate was 94.3% (100/106), and the occlusion rate was 100.0% (100/100). There were one tamponade, one ischemic stroke, and eight minor pericardial effusions during hospitalization. During 12-month follow-up period, two patients developed a thrombus layer on the device that resolved with additional anticoagulation: one with visible device-thrombus experienced transient ischemic stroke, and one had a hemorrhagic stroke. There were no deaths in this study. The overall survival rate was 100.0%, and nonmajor adverse event rate was 95.0% (95/100). In this study, the expected annual rate of ischemic stroke risk in these patients according to the CHA2DS2-VASc score was 4.0%, while the observed ischemic stroke rate was 2.0% per year. CONCLUSIONS LAA closure with the WATCHMAN Device was feasible, efficient, and safe for NVAF to prevent the accidence of stroke in Chinese patients. During the 12-month follow-up period, the observed ischemic stroke rate (2.0% per year) in our study was lower than the predicted annual stroke risk (4.0%) using the CHA2DS2-VASc score.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous left atrial appendage closure for stroke prophylaxis in patients with atrial fibrillation: 2.3-Year Follow-up of the PROTECT AF (Watchman Left Atrial Appendage System for Embolic Protection in Patients with Atrial Fibrillation) Trial.

BACKGROUND The multicenter PROTECT AF study (Watchman Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) was conducted to determine whether percutaneous left atrial appendage closure with a filter device (Watchman) was noninferior to warfarin for stroke prevention in atrial fibrillation. METHODS AND RESULTS Patients (n=707) with nonvalvular atrial fibril...

متن کامل

Left Atrial Appendage Closure With the Watchman Device in Patients With a Contraindication for Oral Anticoagulation

Helmsley Electrophysiolo New York; yUniversity Department, Homo ular Center Frankfurt, n Bruder, Regensburg, G he ASAP trial. Drs. Redd received grant support an r of the Watchman device tionships relevant to the c pt received December 26 ed March 19, 2013. he purpose of this study was to assess the safety and efficacy of left atrial appendage (LAA) closure in nonvalvular atrial fibrillation (A...

متن کامل

Prospective randomized evaluation of the Watchman Left Atrial Appendage Closure device in patients with atrial fibrillation versus long-term warfarin therapy: the PREVAIL trial.

BACKGROUND In the PROTECT AF (Watchman Left Atrial Appendage Closure Technology for Embolic Protection in Patients With Atrial Fibrillation) trial that evaluated patients with nonvalvular atrial fibrillation (NVAF), left atrial appendage (LAA) occlusion was noninferior to warfarin for stroke prevention, but a periprocedural safety hazard was identified. OBJECTIVES The goal of this study was t...

متن کامل

Left Atrial Appendage Closure as an Alternative to Warfarin for Stroke Prevention in Atrial Fibrillation: A Patient-Level Meta-Analysis.

BACKGROUND The risk-benefit ratio of left atrial appendage closure (LAAC) versus systemic therapy (warfarin) for prevention of stroke, systemic embolism, and cardiovascular death in nonvalvular atrial fibrillation (NVAF) requires continued evaluation. OBJECTIVES This study sought to assess composite data regarding left atrial appendage closure (LAAC) in 2 randomized trials compared to warfari...

متن کامل

Left atrial appendage exclusion for stroke prevention in patients with nonrheumatic atrial fibrillation.

The efficacy of oral anticoagulation (OAC) for stroke prevention in patients with nonrheumatic atrial fibrillation (AF) has clearly been established. However, a substantial number of patients with AF who are at high risk for thromboembolic events are not candidates for long-term OAC. The left atrial appendix (LAA) is the most common place of thrombosis in patients with AF, and it can easily be ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 130  شماره 

صفحات  -

تاریخ انتشار 2017