Comparison of the accuracy of ventricular catheter placement using freehand placement, ultrasonic guidance, and stereotactic neuronavigation.

نویسندگان

  • Thomas J Wilson
  • William R Stetler
  • Wajd N Al-Holou
  • Stephen E Sullivan
چکیده

OBJECT The objective of this study was to compare the accuracy of 3 methods of ventricular catheter placement during CSF shunt operations: the freehand technique using surface anatomy, ultrasonic guidance, and stereotactic neuronavigation. METHODS This retrospective cohort study included all patients from a single institution who underwent a ventricular CSF shunting procedure in which a new ventricular catheter was placed between January 2005 and March 2010. Data abstracted for each patient included age, sex, diagnosis, method of ventricular catheter placement, site and side of ventricular catheter placement, Evans ratio, and bifrontal ventricular span. Postoperative radiographic studies were reviewed for accuracy of ventricular catheter placement. Medical records were also reviewed for evidence of shunt failure requiring revision through December 2011. Statistical analysis was then performed comparing the 3 methods of ventricular catheter placement and to determine risk factors for inaccurate placement. RESULTS There were 249 patients included in the study; 170 ventricular catheters were freehand passed, 51 were placed using stereotactic neuronavigation, and 28 were placed under intraoperative ultrasonic guidance. There was a statistically significant difference between freehand catheters and stereotactic-guided catheters (p<0.001), as well as between freehand catheters and ultrasound-guided catheters (p<0.001). The only risk factor for inaccurate placement identified in this study was use of the freehand technique. The use of stereotactic neuronavigation and ultrasonic guidance reduced proximal shunt failure rates (p<0.05) in comparison with a freehand technique. CONCLUSIONS Stereotactic- and ultrasound-guided ventricular catheter placements are significantly more accurate than freehand placement, and the use of these intraoperative guidance techniques reduced proximal shunt failure in this study.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Guided Application of Ventricular Catheters (GAVCA) - multicentre study to compare the ventricular catheter position after use of a catheter guide versus freehand application: study protocol for a randomised trail

BACKGROUND The standard technique for the placement of ventricular catheters (VC) comprises a high proportion of malpositioning of the catheter (12.5 to 40%). Technical advances such as neuronavigation or ultrasound have been shown to increase the accuracy of the procedure. Since these means result in significant technical and time consuming efforts, they are used for selected cases only. In or...

متن کامل

Endoscopic-Assisted Ommaya Reservoir Placement: Technical Note

Ommaya reservoir placement has been an option for patients requiring cerebrospinal fluid (CSF) access since the 1960s. It is preferred to repeat lumbar punctures, both in terms of patient comfort and the consistency of intrathecal drug concentration. Technological developments have advanced the placement technique, allowing for better accuracy and reduced complications. Freehand placement was f...

متن کامل

Principles of Neuronavigation

Background and Aim: Numerous efforts over the past century have been performed. Various innovation techniques are increasingly gaining attention and gradually established the foundation of recent significant developments in the world of neurosurgery, among which varied stereotactic neuro-navigation designs and other novel emerging systems are being quotidian developed. This narrative review ai...

متن کامل

Application of the ISYS1 robotic device for stereotactic neurosurgical interventions: a preclinical phantom trial

Submillimetric precision is essential for stereotactic neurosurgical procedures. However, accuracy of standard neuro-surgical procedures such as navigated biopsies and shunts is currently limited due to manual alignment of the biopsy needle or manual placement of the shunt catheter. The aim of this study is to evaluate the feasibility and accuracy of a novel robotic positioning device for stere...

متن کامل

Accuracy Assessment of Freehand Pedicular Screw Placement

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of neurosurgery

دوره 119 1  شماره 

صفحات  -

تاریخ انتشار 2013