Lexical tone perception with HiResolution and HiResolution 120 sound-processing strategies in pediatric Mandarin-speaking cochlear implant users.

نویسندگان

  • Demin Han
  • Bo Liu
  • Ning Zhou
  • Xueqing Chen
  • Ying Kong
  • Haihong Liu
  • Yan Zheng
  • Li Xu
چکیده

OBJECTIVES Lexical tone recognition tends to be poor in cochlear implant users. The HiResolution (HiRes) sound-processing strategy is designed to better preserve temporal fine structure, or the detailed envelope information, of an acoustic signal. The newer HiRes 120 strategy builds on HiRes by increasing the amount of potential spectral information delivered to the implant user. The purpose of this study was to examine lexical tone recognition in native Mandarin Chinese-speaking children with cochlear implants using the HiRes and HiRes 120 sound-processing strategies. Tone recognition performance was tested with HiRes at baseline and then after up to 6 mo of HiRes 120 experience in the same subjects. DESIGN Twenty prelingually deafened, native Mandarin-speaking children, with ages ranging from 3.5 to 16.5 yr, participated. All children completed a computerized tone contrast test on three occasions: (1) using HiRes immediately before conversion to HiRes 120 (baseline), (2) 1 mo after conversion, and (3) 3 mo after conversion. Twelve of the 20 children also were tested 6 mo after conversion. In addition, the parents of 18 children completed a questionnaire at the 3-mo follow-up visit regarding the preference of sound-processing strategies and the children's experience related to various aspects of auditory perception and speech production using HiRes 120. RESULTS As a group, no statistically significant differences were seen between the tone recognition scores using HiRes and HiRes 120. Individual scores showed great variability. Tone recognition performance ranged from chance (50% correct) to nearly perfect. Using the conventional HiRes strategy, 6 of the 20 children achieved high-level tone recognition performance (i.e., >or=90% correct), whereas 7 performed at a level not significantly different from chance (50-60% correct). At the final test, either 3 or 6 mo after conversion, all children achieved tone recognition performance with HiRes 120 that was equal to or better than that with HiRes, although some children's tone recognition performance was worse initially at the 1 or 3 mo follow-up intervals than at baseline. Eight of the 20 children showed statistically significant improvement in tone recognition performance with HiRes 120 on at least one of the follow-up tests. Age at implantation was correlated with tone recognition performance at all four test intervals. Parents of most of the children indicated that the children preferred HiRes 120 more than HiRes. CONCLUSIONS As a group, HiRes 120 did not provide significantly improved lexical tone recognition compared to HiRes, at least throughout the length of the study (up to 6 mo). There were large individual differences in lexical tone recognition among the prelingually deafened, native Mandarin-speaking children with cochlear implants using either HiRes or HiRes 120. Six of the 20 children performed at or near ceiling in the baseline HiRes condition. Of the remainder, approximately half showed significantly better tone recognition when subsequently tested with HiRes 120, although the extent to which this improvement may be attributable to factors other than the change in processing strategy (e.g., general development) is unknown. The children who benefited most from HiRes 120 tended to be those who were implanted at younger ages.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the ClearVoice Strategy in Adults Using HiResolution Fidelity 120 Sound Processing

OBJECTIVES This study aimed to evaluate the benefits of ClearVoice strategy on speech perception in noise and in everyday listening situations in Cantonese-speaking cochlear implant users. METHODS Twelve experienced adult users of the Harmony implant and HiRes 120 sound processing participated in the study. The study employed a prospective within-subjects design wherein speech recognition in ...

متن کامل

Effects of converting bilateral cochlear implant subjects to a strategy with increased rate and number of channels.

OBJECTIVES Three different Advanced Bionics processing strategies were evaluated: 1) 8-channel, 813 pulses per second (pps), Continuous Interleaved Sampling (CIS); 2) 16-channel, 5,100 pps, HiResolution Paired (HiRes P); and 3) 16-channel, 2,900 pps, HiResolution Sequential (HiRes S). METHODS Seven adult bilateral Clarion CII cochlear implant recipients who had been using a CIS processing str...

متن کامل

Music Training Can Improve Music and Speech Perception in Pediatric Mandarin-Speaking Cochlear Implant Users

Due to limited spectral resolution, cochlear implants (CIs) do not convey pitch information very well. Pitch cues are important for perception of music and tonal language; it is possible that music training may improve performance in both listening tasks. In this study, we investigated music training outcomes in terms of perception of music, lexical tones, and sentences in 22 young (4.8 to 9.3 ...

متن کامل

New Methodology for Fitting Cochlear Implants

Sound coding strategies for cochlear implants have evolved over the past 30 years with advances in research and technology. Processing schemes have transitioned from the delivery of a diffuse, broad signal in single channel devices to the transmission of detailed sound information to multi-channel devices. This evolution has involved the addition of more channels and more parameter options for ...

متن کامل

Relationship between tone perception and production in prelingually deafened children with cochlear implants.

HYPOTHESIS Performance in tone perception and production are correlated in prelingually deafened pediatric cochlear implant (CI) users across individuals. Demographic variables, such as age at implantation, contribute to the performance variability. BACKGROUND Poor representation of pitch information in CI devices hinders pitch perception and affects perception of lexical tones in cochlear im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ear and hearing

دوره 30 2  شماره 

صفحات  -

تاریخ انتشار 2009