Are estimates of MAC reliable?
نویسندگان
چکیده
BACKGROUND Potency of inhaled anesthetics (minimum alveolar concentration [MAC]) is typically studied in humans using an "up-down" approach in which the (quantal) response to skin incision is assessed only once for each individual, so that each individual's MAC is never determined. The authors examined the influence of interindividual variability and study design issues (e.g., the number of patients enrolled in a study) on the accuracy of MAC estimates. METHODS The typical sequence of a MAC study was simulated. The authors varied and tested the impact of several factors: anesthetic concentration used to start a study; number of "crossovers" (successive patients having different responses to skin incision) to terminate a study; concentration increment between consecutive patients; interindividual variability; and "measurement error." For each factor, simulations were replicated 500 times, and the resulting estimates were summarized. RESULTS Starting an experiment below or above the "true" value led to slightly biased MAC estimates; in contrast, variability was underestimated with starting concentrations close to the true value. More than six crossovers improved MAC estimates minimally but increased variability estimates toward true values. A larger increment size affected MAC minimally and increased variability estimates toward true values. A larger interindividual variability led to more "outlier" estimates for MAC. Under many conditions, several of 500 replicates yielded MAC estimates that deviated more than 10% or even more than 25% from the "true" value. CONCLUSION Individual experiments may yield inaccurate MAC estimates. This inaccuracy is minimized as the number of crossovers increases; however, improvement diminishes as the number of crossovers exceeds six.
منابع مشابه
Data and Methods for the Production of National Population Estimates: An Overview and Analysis of Available Metadata
Thomas Spoorenberg Translated by: Elham Fathi Statistical Center of Iran Abstract. Official population estimates can be produced using a variety of data sources and methods. These range from the direct extraction of information from continuously updated population registers to procedures for updating the status of a population enumerated previously in a periodic census. Additional sources and ...
متن کاملPatterns of Maternal Weight Gain During Pregnancy and Birth Weight
Anthropometric parameters are an important indicator of health and nutritional status comprising the whole span of mans life. However, they are not of the same degree of simplicity and sensitivity in assessing the public health status. During recent decades many studies have attempted to examine the relationships of these measurements in order to present simple alternatives for similar purposes...
متن کاملMulti-channel Medium Access Control Protocols for Wireless Sensor Networks: A Survey
Extensive researches on Wireless Sensor Networks (WSNs) have been performed and many techniques have been developed for the data link (MAC) layer. Most of them assume single-channel MAC protocols. In the usual dense deployment of the sensor networks, single-channel MAC protocols may be deficient because of radio collisions and limited bandwidth. Hence, using multiple channels can significantly ...
متن کاملMulti-channel Medium Access Control Protocols for Wireless Sensor Networks: A Survey
Extensive researches on Wireless Sensor Networks (WSNs) have been performed and many techniques have been developed for the data link (MAC) layer. Most of them assume single-channel MAC protocols. In the usual dense deployment of the sensor networks, single-channel MAC protocols may be deficient because of radio collisions and limited bandwidth. Hence, using multiple channels can significantly ...
متن کاملThe regional estimates of the GPS satellite and receiver differential code biases
The Differential Code Biases (DCB), which are also termed hardware delay biases, are the frequency-dependent time delays of the satellite and receiver. Possible sources of these delays are antennas and cables, as well as different filters used in receivers and satellites. These instrumental delays affect both code and carrier measurements. These biases for satellites and some IGS stations tend ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 95 6 شماره
صفحات -
تاریخ انتشار 2001