Evaluation of the BBL Crystal Anaerobe identification system.

نویسندگان

  • J J Cavallaro
  • L S Wiggs
  • J M Miller
چکیده

The BBL Crystal Anaerobe (ANR) identification system was evaluated, and the results were compared with those from conventional anaerobic methods. We tested 322 clinically significant anaerobic bacteria according to the manufacturer's instructions. The system identified correctly 286 of 322 (88.8%) of the anaerobic bacteria tested. Of these, 263 of 322 (81.7%) were identified correctly on initial testing and 49 were identified correctly only to the genus level; on repeat testing, 23 of 49 (46.9%) were identified correctly to both the genus and the species levels. A total of 26 (8.5%) were misidentified at the species level, and 10 (3.1%) were not identified. Performance characteristics for individual strains varied. The system correctly identified all tested strains of Campylobacter, Desulfomonas, Desulfovibrio, Leptotrichia, Mobiluncus, Peptostreptococcus, Porphyromonas, Provetella, Propionibacterium, Tisierella, and Veillonella and 36 of 37 (97.3%) Actinomyces strains, 42 of 46 (91.3%) B. fragilis group strains, 79 of 103 (76.7%) Clostridium strains, (however, the system failed to identify any of the 7 C. innocuum and 9 C. tetani strains tested), and 8 of 15 (53.3%) Bacteroides strains. This system was easy to use, did not involve the addition of reagents, and was faster than conventional anaerobic procedures. It would be a useful addition to the anaerobe laboratory of most hospitals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of AnaeroGen system for growth of anaerobic bacteria.

The Oxoid AnaeroGen system was compared with the BBL GasPak for the production of an anaerobic atmosphere and was evaluated for its ability to support the growth of 135 clinically significant anaerobic bacteria. An anaerobe chamber was used as the "gold standard" for supporting the growth of anaerobes. The AnaeroGen requires no catalyst, produces no hydrogen, requires no water, and reduces prep...

متن کامل

Identification of Yersinia pestis by BBL Crystal Enteric/Nonfermenter Identification System.

The BBL Crystal Enteric/Nonfermenter System (Crystal) was used to test 25 archived isolates of Yersinia pestis to obtain a unique biochemical profile code for Y. pestis. The revised Crystal system and the API 20E system were compared by using 12 clinical human isolates of Y. pestis. Crystal correctly identified 11 of the 12 isolates, while API correctly identified 7 of the 12 isolates.

متن کامل

Evaluation of the BBL Crystal MRSA ID System for detection of oxacillin resistance in Staphylococcus aureus.

AIMS To evaluate the BBL Crystal MRSA ID System for detection of oxacillin resistance in Staphylococcus aureus. METHODS 52 methicillin resistant S aureus (MRSA) from five different countries and 85 methicillin susceptible S aureus (MSSA) were included. The species was confirmed by tube coagulation and detection of the clumping factor using the Staphaurex Plus. Clonal non-identity of the MRSA ...

متن کامل

Evaluation of three rapid methods for detection of methicillin resistance in Staphylococcus aureus.

The probe-based Velogene Rapid MRSA Identification Assay (ID Biomedical Corp., Vancouver, British Columbia, Canada) and the latex agglutination MRSA-Screen (Denka Seiken Co., Tokyo, Japan) were evaluated for their ability to identify methicillin-resistant Staphylococcus aureus (MRSA) and to distinguish strains of MRSA from borderline oxacillin-resistant S. aureus (BORSA; mecA-negative, oxacilli...

متن کامل

Technical report Evaluation of the BBL Crystal MRSA ID System for detection of oxacillin resistance in Staphylococcus aureus

Aims—To evaluate the BBL® CrystalTM MRSA ID System for detection of oxacillin resistance in Staphylococcus aureus. Methods—52 methicillin resistant S aureus (MRSA) from five diVerent countries and 85 methicillin susceptible S aureus (MSSA) were included. The species was confirmed by tube coagulation and detection of the clumping factor using the Staphaurex Plus. Clonal non-identity of the MRSA ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 35 12  شماره 

صفحات  -

تاریخ انتشار 1997