Heat pipes have immense potential in the future of thermal management in electronic devices. As a passive device, they rely solely upon capillary forces to recirculate the coolant from the condenser to the evaporator via a wicking structure. In intermediate temperature heat pipes the limiting factor for heat removal is the capillary limit, which indicates the maximum recirculation rate that the capillary forces can induce. This capillary limit must be increased to allow heat pipes to remain a viable option for heat management within electronic devices. The aim of this work is to characterize and optimize the capillary limit of micropillared thermal wicks for heat pipe application in microelectronics cooling. Towards this goal, an analytical model, and a novel thermohydraulic experimental setup was developed. The analytical model of the micropillared array wicking structure provides a theoretical basis from which the pillar geometry and arrangement can be optimized. A capillary limit model was used to determine the geometric relationship between the pillar arrays and the maximum capillary flow rate through the wick. This model considers the effects of gravity and mass transfer due to evapo-

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of the thermo-hydraulic behavior of the fluid flow over a square ribbed channel

The thermo-hydraulic behavior of the air flow over a two dimensional ribbed channel wasnumerically investigated in various rib-width ratio configurations (B/H=0.5-1.75) atdifferent Reynolds numbers, ranging from 6000 to 18000. The capability of differentturbulence models, including standard k-ε, RNG k-ε, standard k-ω, and SST k-ω, inpredicting the heat transfer rate was compared with the experi...

متن کامل

Controlling thermo-optic response in microresonators using bimaterial cantilevers.

We demonstrate a novel platform to control the thermo-optic sensitivity in nanophotonic devices by evanescent coupling of light with bimaterial cantilevers. The cantilever can be designed to provide a negative thermal feedback to passively compensate for the positive thermo-optic effect in the waveguide core. We demonstrate athermal operation over 14 deg in cantilever coupled Silicon ring reson...

متن کامل

Evaluation of a Novel Thermobrachytherapy Seed for Concurrent Administration of Brachytherapy and Magnetically Mediated Hyperthermia in Treatment of Solid Tumors

Concurrent hyperthermia and radiation therapy in treatment of cancer show a strong evidence of a synergistic enhancement. We designed a new self-regulating Thermo-Brachytherapy seed, which serves as a source of both radiation and heat for concurrent administration of brachytherapy and hyperthermia. The Thermo-Brachytherapy seed has a core of ferromagnetic material which produces heat when subje...

متن کامل

THERMO-MECHANICAL DESIGN OPTIMIZATION OF CORDIERITE–MULLITE BASED KILN FURNITURE

Abstract: Cordierite-Mullite based kiln furnitures are widely used in fast-firing of ceramic products because of their low thermal expansion which confer them a very good ability to thermal shock resistance. Difference in CTE of constituent phase can develop damage during thermal cycling due to internal stresses. Increase in industrial competitiveness leads to the development of new means for e...

متن کامل

Evaluation of the thermal and hydraulic performances of a very thin sintered copper flat heat pipe for 3D microsystem packages

The reported research work presents numerical studies validated by experimental results of a flat micro heat pipe with sintered copper wick structure. The objectives of this research were to produce and demonstrate the efficiency of the passive cooling technology (heat pipe) integrated in a very thin electronic substrate that is a part of a multifunctional 3-D electronic package. The enhanced t...