Separation-free electrochemical immunosensor for rapid determination of atrazine.
نویسندگان
چکیده
A separation-free electrochemical immunoassay method for the detection of the pesticide atrazine is described. The method developed is a competitive ELISA incorporating disposable screen printed horseradish peroxidase modified electrodes as the detector element in conjunction with single-use atrazine immuno-membranes. Screen printed carbon electrodes were prepared using carbon ink incorporating horseradish peroxidase. A monoclonal antibody for atrazine was immobilised onto Biodyne C membranes which were, in turn, placed over the electrode surface. The assay was based on competition for available binding sites between free atrazine and an atrazine-glucose oxidase conjugate prepared 'in-house'. In the presence of glucose, H2O2 formed by the conjugate was reduced by enzyme-channelling via the HRP electrode. The HRP was in turn re-reduced by a direct electron transfer mechanism at a potential of +50 mV Vs Ag/AgCl. Any H2O2 formed in the bulk solution by unbound atrazine-GOD conjugate was scavenged by excess catalase thus removing the requirement for a washing step. The performance of the method was compared with a commercial immunoassay kit for atrazine.
منابع مشابه
Fabrication of an Electrochemical Immunosensor for Determination of Human Chorionic Gonadotropin Based on PtNPs/Cysteamine/AgNPs as an Efficient Interface
An ultrasensitive electrochemical immunosensor for the detection of tumor marker human chorionic gonadotropin (hCG) was developed with a limit of detection as low as 2 pg mL-1 in phosphate buffer. The Platinum nanoparticles (PtNPs) were electrodeposited to modify the gold surface and to increase enlarging the electrochemically active sites, resulting in the facilitation of electron exchange. Cy...
متن کاملNovel amperometric immunosensor for rapid separation-free immunoassay of carcinoembryonic antigen.
A novel immunosensor for rapid separation-free determination of carcinoembryonic antigen (CEA) in human serum is proposed. The immunosensor is prepared by co-immobilizing thionine and horseradish peroxidase (HRP)-labeled CEA antibody on a glassy carbon electrode (GCE) through covalently binding them to GCE with a glutaraldehyde (GA) linkage. The electrochemical behavior of the immobilized thion...
متن کاملAmperometric separation-free immunosensor for real-time environmental monitoring
Immunoanalytical techniques have found widespread use due to the characteristics of specificity and wide applicability for many analytes, from large polymer antigens, to simple haptens, and even single atoms. Electrochemical sensors offer benefits of technical simplicity, speed and convenience via direct transduction to electronic equipment. Together, these two systems offer the possibility of ...
متن کاملUsing Boehmite Nanoparticles as an Undercoat, and Riboflavin as a Redox Probe for Immunosensor Designing: Ultrasensitive Detection of Hepatitis C Virus Core Antigen
In this study a label-free electrochemical Immunosensor for ultrasensitive detection of Hepatitis C virus core antigen in serum samples was fabricated by using a simple approach. In this method a low-cost and sensitive immunosensor was fabricated based on a boehmite nanoparticles (BNPs) modified glassy carbon. The BNPs provide a specific platform with increased surface area which is capable of ...
متن کاملElectrochemical Immunosensor Based on Polythionine/Gold Nanoparticles for the Determination of Aflatoxin B1
An aflatoxin B₁ (AFB₁) electrochemical immunosensor was developed by the immobilisation of aflatoxin B₁-bovine serum albumin (AFB₁-BSA) conjugate on a polythionine (PTH)/gold nanoparticles (AuNP)-modified glassy carbon electrode (GCE). The surface of the AFB₁-BSA conjugate was covered with horseradish peroxidase (HRP), in order to prevent non-specific binding of the immunosensors with ions in t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biosensors & bioelectronics
دوره 13 9 شماره
صفحات -
تاریخ انتشار 1998