Invivo Dosimetry for Mammography with and without Lead Apron Using the Glass Dosimeters
نویسندگان
چکیده
93 This research was supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education, Science and Technology (2010-0013701 and 2013R1A1A2012013). Received 16 May 2015, Revised 17 June 2015, Accepted 19 June 2015 Correspondence: Samju Cho ([email protected]) Tel: 82-2-2228-4390, Fax: 82-2-2227-7823 cc This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. Invivo Dosimetry for Mammography with and without Lead Apron Using the Glass Dosimeters
منابع مشابه
Evaluation of Occupational Radiation Status and Validity of Individual Dose and Eye Lens Assessment Using Single Film Dosimeter for Angiographic Staff in Iran
Background and Aim: In angiography, the lens of the eye may be exposed to radiation and cause cataracts. In Iran, at present, only a single film dosimeter is used under the lead-apron to evaluate individual doses. The aim of this study was to investigate the status of occupational radiation as well as the validity of measuring the dose of the whole body of individuals and eye lenses using a sin...
متن کاملStudy on influence of X-ray baggage scan on ESR dosimetry for SNTS using human tooth enamel.
The influence of X-ray baggage scanning on electron spin resonance (ESR) dosimetry studies around the Semipalatinsk Nuclear Test Site (SNTS) has been examined at Incheon Airport in Korea, which is a transfer point of the routes from Kazakhstan to Japan. Utilized dosimeters are Japanese human tooth enamel for ESR and glass dosimeters. The difference between the estimated doses with the X-ray sca...
متن کاملAre Radiation Exposure Levels Used in Cardiology Dangerous?
Background: The number of interventional cardiology procedures performed has increased rapidly over the past years. While these procedures help physicians avoid using highly complicated invasive methods, it usually leads to high levels of exposure to ionizing radiation of both patients and cardiologist. The dose received by the cardiologist during interventional cardiology procedures is determi...
متن کاملRadiation Exposure to the Hand of a Spinal Interventionalist during Fluoroscopically Guided Procedures
STUDY DESIGN Prospective study. PURPOSE During fluoroscopically guided spinal procedure, the hands of spinal surgeons are placed close to the field of radiation and may be exposed to ionizing radiation. This study directly measured the radiation exposure to the hand of a spinal interventionalist during fluoroscopically guided procedures. OVERVIEW OF LITERATURE Fluoroscopically guided spinal...
متن کاملEvaluation of a radiation protection cabin for invasive electrophysiological procedures.
AIMS Complex invasive electrophysiological procedures may result in high cumulative operator radiation exposure. Classical protection with lead aprons results in discomfort while radioprotection is still incomplete. This study evaluated the usefulness of a radiation protection cabin (RPC) that completely surrounds the operator. METHODS AND RESULTS The evaluation was performed independently in...