Long-term effects in distal coronary anastomoses using different adhesives in a porcine off-pump model.

نویسندگان

  • Jens Wippermann
  • Christo Konstas
  • Martin Breuer
  • Hartwig Kosmehl
  • Thorsten Wahlers
  • Johannes M Albes
چکیده

OBJECTIVE Adhesives are useful supplements to seal distal coronary anastomoses, particularly in patients who receive less-invasive coupling techniques. Information regarding long-term structural effects after application, however, is limited. The purpose of this large animal study was to examine the effects of 3 different commercially available surgical adhesives. METHODS Twelve end-to-side anastomoses were created between the left internal thoracic artery and the left anterior descending coronary artery in a porcine beating heart model. Three different adhesives were applied externally and circumferentially to the anastomosis site. In group I (n = 4) gelatin-resorcinol-formaldehyde glue (Cardial, Technopole, Sainte-Etienne, France), in group II (n = 4) n-butyl-2-cyanoacrylate glue, and in group III (n = 4) albumin-glutaraldehyde glue were used. All anastomoses were examined intraoperatively by flow measurement. After 3 months the anastomoses were reassessed for patency and the vessels were evaluated histologically. RESULTS By means of 4 stay sutures and subsequent glue application, anastomoses could be created successfully on the first attempt in all animals. Perioperative flow through the left internal thoracic artery was similar in all groups. In 4 animals an additional suture was placed to control bleeding. After 3 months, the patency rate was 83.3% (10/12). In group I all anastomoses were patent whereas in both groups II and III one anastomosis was occluded. None of the adhesives caused impaired vessel wall healing but they did demonstrate moderate-to-dense adhesions to the surrounding tissue. On histologic examination, gelantin-resorcinol-formaldehyde glue exhibited minimal tissue reaction (foreign-body granuloma) whereas n-butyl-2-cyanoacrylate glue showed moderate reaction. In contrast, albumin-glutaraldehyde glue caused severe inflammatory reaction with extensive fibroblastic proliferation. CONCLUSION Construction of an end-to-side internal thoracic artery-coronary artery sleeve anastomosis using adhesives was feasible in the pig. Among the tissue adhesives used in this study, gelantin-resorcinol-formaldehyde glue appeared to be superior to cyanoacrylate and albumin-glutaraldehyde glue. The latter one, however, caused severe adverse histologic effects and thus cannot be recommended for bonding coronary anastomoses.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a novel 2 mm internal diameter stainless steel saphenous vein to coronary artery connector: laboratory studies of on-pump and off-pump revascularization.

OBJECTIVE A second generation, 'easy-load', 2 mm internal diameter (ID), stainless steel, distal anastomotic device has been developed, and design improvements facilitate rapid connector loading with minimal magnification. The reduced size should allow application to most distal coronary vessels currently grafted. This technology may be useful in off-pump and minimally invasive surgical approac...

متن کامل

Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model

To simplify and facilitate beating heart (i.e., off-pump), minimally invasive coronary artery bypass surgery, a new coronary anastomotic connector, the Trinity Clip, is developed based on the excimer laser-assisted nonocclusive anastomosis technique. The Trinity Clip connector enables simplified, sutureless, and nonocclusive connection of the graft to the coronary artery, and an excimer laser c...

متن کامل

Comparison of Unstable Hemodynamic Patients Undergoing Coronary Artery Bypass Graft Surgery with on- or off-Pump Methods

Introduction: Coronary artery disease (CAD) is the most common type of heart disease, with a mortality rate of 385,000 person per year in the United States. There are two main methods for CAD treatments: angioplasty and bypass surgery. Coronary Artery Bypass Grafting (CABG) is one of the greatest surgical operations of the 20th century and it is presented as most effective and long-term therapi...

متن کامل

Geometry assessment of coronary artery anastomoses with construction errors by epicardial ultrasound.

OBJECTIVE There is concern about the quality of the distal anastomosis in off-pump coronary artery bypass grafting. We investigated the impact of specific construction errors on anastomotic geometry using epicardial ultrasound. METHODS Twelve ex vivo pressure perfused porcine and five isolated post-mortem human hearts were used to construct 35 internal mammary artery to coronary artery anasto...

متن کامل

The Monoshunt: a new intracoronary shunt design to avoid distal endothelial dysfunction during off-pump coronary artery bypass (OPCAB).

Insertion of intracoronary shunts during off-pump coronary artery bypass surgery can induce a severe endothelial dysfunction. The purpose of this study was to propose a new intracoronary shunt design called Monoshunt, to avoid distal endothelial damage of the target artery in a porcine model. The use of the Monoshunt avoids distal endothelial denudation and allows distal coronary perfusion.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of thoracic and cardiovascular surgery

دوره 132 2  شماره 

صفحات  -

تاریخ انتشار 2006