Wide-angle chromatic aberration corrector for the human eye.

نویسندگان

  • Yael Benny
  • Silvestre Manzanera
  • Pedro M Prieto
  • Erez N Ribak
  • Pablo Artal
چکیده

The human eye is affected by large chromatic aberration. This may limit vision and makes it difficult to see fine retinal details in ophthalmoscopy. We designed and built a two-triplet system for correcting the average longitudinal chromatic aberration of the eye while keeping a reasonably wide field of view. Measurements in real eyes were conducted to examine the level and optical quality of the correction. We also performed some tests to evaluate the effect of the corrector on visual performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Construction of special eye models for investigation of chromatic and higher-order aberrations of eyes.

An achromatic element eliminating only longitudinal chromatic aberration (LCA) while maintaining transverse chromatic aberration (TCA) is established for the eye model, which involves the angle formed by the visual and optical axis. To investigate the impacts of higher-order aberrations on vision, the actual data of higher-order aberrations of human eyes with three typical levels are introduced...

متن کامل

Study on chromatic aberration in a population of Chinese myopic eyes by means of optical design

Two kinds of individual eye models, involving and without involving the angle between visual axis and optical axis, are established by means of optical design. We use them to study the properties of the transverse chromatic aberration (TCA) and longitudinal chromatic aberration (LCA) over the visible spectrum. Then the effects of the LCA and TCA on the visual quality of human eyes are evaluated...

متن کامل

Resolution Enhancement at Low-Accelerating-Voltage by Improvements of Diffraction Limit and Chromatic Aberration

An atomic-resolution microscope operating at a lower voltage is increasingly requested because the lower accelerating voltage provides less specimen damage and larger scattering cross-section that results in a high signal for analysis [1-3]. However, a resolution reduction by a diffraction limit becomes severe with an increase in the wavelength of an electron as an accelerating voltage decrease...

متن کامل

A Wide-angle Gradient Index Optical Model of the Crystalline Lens and Eye of the Rainbow Trout

Trout lens external shape and internal refractive index gradient structure were measured and used to construct an optical lens model that predicts by ray tracing the average longitudinal spherical and chromatic aberration, focal length and image quality. The nearly spherical shape of the lens was measured from photographs, and the internal refractive gradient structure was measured directly wit...

متن کامل

Benefits and Possibilities of Cc–Correction for TEM / STEM

During the last decade aberration correction became possible for several types of electron optical instruments. Correctors for the spherical aberration of TEM / STEM objective lenses are now commercially available [1,2]. In case of the SEM [3] and the LEEM / PEEM [4] the correction of both the spherical and the chromatic aberration has been demonstrated in experiments. In spite of these great a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Optical Society of America. A, Optics, image science, and vision

دوره 24 6  شماره 

صفحات  -

تاریخ انتشار 2007