Mechanisms and developments of magnetic source MRI

نویسندگان

  • Yiqun Xue
  • Jinhu Xiong
چکیده

Magnetic source MRI (msMRI) has been developed recently for direct detections of neuronal magnetic fields to map brain activity. However, whether MRI can be used for direct detection of neuronal activity is a matter of debate. Controversial theoretical and experimental results have been reported. In this work, theoretical modeling and experimental validation have been presented to demonstrate that the neuronal current signal is in the detectable range and could be detected by MRI. In the theoretical modeling section, we present an improved current-dipole model to compute magnetic field generated by neural firing and to calculate MRI signal changes resulting from the neuronal magnetic field. Neuronal magnetic field were estimated based on a synchronized activity of multiple neurons. Our results show that neuronal magnetic field can potentially generate up to a few percent changes in MRI magnitude signals. Phases of MRI signal tend to be destructively added and are insensitive to neuronal magnetic field in the activated region when the distribution of the activated dendrites is symmetrical. Our modeling implies that direct MRI detection of neuronal activity is possible. In the experimental validation section, a rapid median nerve stimulation paradigm has been used to detect the neuronal activity. The experiments were performed on six normal human participants to investigate the temporal specificity of the effect, as well as interand intra-subject reproducibility. Significant activation of contra-lateral primary sensory cortex (S1) was detected 80ms after stimulation onset (corresponding to the P80 evoked potential peak). The 80 ms latency S1 activation was observed over 3 independent sessions for one subject and for all 6 participants. The magnitude of the signal change was 0.2% 0.3%. Coinciding with our expectations, no S1 activation was

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recent developments in Pseudomonas biocontrol mechanisms

Fluorescent pseudomonads are an effective source of biological control that have high adaptive power and able to produce a wonderful source of secondary metabolites. Antibiotics such as phenazines, diacetylphloroglucinol, and hydrogen cyanide are produced by certain taxonomic groups of the genus Pseudomonas and appear to be ancestral. These compounds often play a physiological role in the produ...

متن کامل

An investigation into the effect of magnetic resonance imaging (MRI) echo time spacing and number of echoes on the sensitivity and dose resolution of PAGATUG polymer-gel dosimeter

Background: There are various methods to read out responses of a polymer-gel dosimeter, among which the Magnetic Resonance Imaging (MRI) technique is the most common one. Optimizing imaging protocols can have significant effect on the sensitivity and the dose resolution of polymer gel dosimeters. This study has investigated the effects of the number of echoes (NOE) and the echo time spacing (ES...

متن کامل

Uncertainty Analysis in MRI-based Polymer Gel Dosimetry

Background: Polymer gel dosimeters combined with magnetic resonance imaging (MRI) can be used for dose verification of advanced radiation therapy techniques. However, the uncertainty of dose map measured by gel dosimeter should be known. The purpose of this study is to investigate the uncertainty related to calibration curve and MRI protocol for MAGIC (Methacrylic and Ascorbic acid in Gelatin I...

متن کامل

Does Exposure to Static Magnetic Fields Generated by Magnetic Resonance Imaging Scanners Raise Safety Problems for Personnel?

MRI workers are occupationally exposed to static and time-varying gradient magnetic fields.  While the 24-hour time-averaged exposure to static magnetic fields is about a few mT, the maximum static field strength can be as high as 500 mT during patient setup. Over the past several years, our laboratory has performed extensive experiments on the health effects of exposure of animal models and h...

متن کامل

Application of Magnetic Resonance Imaging (MRI) as a safe & Application of Magnetic Resonance Imaging (MRI) as a safe & non-destructive method for monitoring of fruit & vegetable in postharvest period

To investigate and control quality, one must be able to measure quality-related attributes. Quality of produce encompasses sensory attributes, nutritive values, chemical constituents, mechanical properties, functional properties and defects. MRI has great potential for evaluating the quality of fruits and vegetables. The equipment now available is not feasible for routine quality testing. The ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015