Automated flow cytometry compared with an automated dipstick reader for urinalysis.

نویسندگان

  • M R Langlois
  • J R Delanghe
  • S R Steyaert
  • K C Everaert
  • M L De Buyzere
چکیده

Recently, the Sysmex UF-100 flow cytometer was developed to automate urinalysis. We compared UF-100 test results with those of an automated dipstick reader. A cross-check of UF-100, dipstick, and microscopic sediment data was performed in 1001 urine samples. Good agreements (P <0.001) were obtained between UF-100 and dipstick data for erythrocytes (r = 0.636) and leukocytes (r = 0.785). Even in urine with low conductivity, the UF-100 could detect lysed erythrocytes. The UF-100 bacterial count was higher among nitrite-positive urine samples (P <0.0001) and was positively correlated with the UF-100 leukocyte count (r = 0.745; P <0.001). In stored urine (24 h), bacterial counts increased, whereas the forward light scatter of leukocytes decreased (P <0.01). Casts and yeast cells reported by the UF-100 should be confirmed by microscopic review because false positives occurred. We suggest that a computer-assisted cross-check of UF-100 and dipstick data allows a clinically acceptable sieving system to reduce the workload of microscopic sediment urinalysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated urinalysis: first experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting.

BACKGROUND Automated analysis of insoluble urine components can reduce the workload of conventional microscopic examination of urine sediment and is possibly helpful for standardization. We compared the diagnostic performance of two automated urine sediment analyzers and combined dipstick/automated urine analysis with that of the traditional dipstick/microscopy algorithm. METHODS A total of 3...

متن کامل

Automated urinalysis and urine dipstick in the emergency evaluation of young febrile children.

OBJECTIVE The performance of automated flow cytometric urinalysis is not well described in pediatric urinary tract infection. We sought to determine the diagnostic performance of automated cell counts and emergency department point-of-care (POC) dipstick urinalyses in the evaluation of young febrile children. METHODS We prospectively identified a convenience sample of febrile pediatric emerge...

متن کامل

Evaluation of urinalysis parameters to predict urinary-tract infection.

We evaluated the performance of automated-flow cytometry, urinalysis dipsticks and microscopic urine sediment analysis as predictors of urinary tract infection. Urine cultures were used as a reference method for comparison. Six-hundred-seventy-five urine samples from hospitalized and not hospitalized patients attended at Hospital Mãe de Deus, Porto Alegre, in south Brazil, were included in the ...

متن کامل

Detection of significant bacteriuria by automated urinalysis using flow cytometry.

A new flow cytometry-based automated urine analyzer, the UF-50, was evaluated for its ability to screen urine samples for significant bacteriuria. One hundred eighty-six urine specimens from patients attending an outpatient clinic of a university-based hospital were examined. The results obtained with the UF-50 were compared with those obtained by conventional quantitative urine culture. The UF...

متن کامل

Retrieval–travel-time model for free-fall-flow-rack automated storage and retrieval system

Automated storage and retrieval systems (AS/RSs) are material handling systems that are frequently used in manufacturing and distribution centers. The modelling of the retrieval–travel time of an AS/RS (expected product delivery time) is practically important, because it allows us to evaluate and improve the system throughput. The free-fall-flow-rack AS/RS has emerged as a new technology for dr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 45 1  شماره 

صفحات  -

تاریخ انتشار 1999