Noninfectious recombinant antigen for detection of St. Louis encephalitis virus-specific antibodies in serum by enzyme-linked immunosorbent assay.

نویسندگان

  • David E Purdy
  • Amanda J Noga
  • Gwong-Jen J Chang
چکیده

Proper surveillance of virus activity and a timely response to viral outbreaks depend upon the rapid diagnosis of viral infections. The immunoglobulin M (IgM) antibody-capture enzyme-linked immunosorbent assay (MAC-ELISA) is a fast, sensitive test routinely used for the diagnosis of the medically important West Nile and St. Louis encephalitis flaviviruses. However, the suckling mouse brain-derived (SMB) antigen used in this assay is tedious to prepare and has a risk of exposing personnel to live virus and hazardous chemicals. We report the development of a St. Louis encephalitis virus (SLEV) noninfectious recombinant antigen that is a safe and easily produced alternative antigen for use in diagnostic assays. The expression plasmid pCB8SJ2, containing the premembrane and envelope structural protein-encoding regions of SLEV, was constructed to express secreted extracellular virus-like particles (VLPs) from CHO cells. Blind-coded human serum panels were assembled from patients having recent SLEV, West Nile virus (WNV), Powassan virus, or La Crosse encephalitis virus infections to assess the sensitivity and specificity of assays with SLEV VLP or SMB antigen. MAC-ELISAs with either antigen had comparable sensitivity for the detection of IgM antibodies against SLEV. Importantly, when these two antigens were tested against a human serum panel from patients having recent WNV or Powassan virus infections, the SLEV VLPs were less likely than SMB antigen to detect flavivirus cross-reactive IgM antibodies. An optimized IgG antibody capture ELISA (GAC-ELISA) with both WNV and SLEV VLPs was developed to circumvent the frequently observed higher background in the antigen-capture IgG-ELISA (ACG-ELISA). For the detection of IgG antibodies against WNV, the GAC-ELISA resulted in a statistically significant higher performance accuracy (P = 0.003) than the ACG-ELISA when the WNV VLP antigen was used in both assays. However, no statistical difference was observed in the assay performance of the GAC-ELISA with SLEV VLP or the ACG-ELISA with SLEV SMB antigen.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A rapid dot immunoassay for the detection of serum antibodies to eastern equine encephalomyelitis and St. Louis encephalitis viruses in sentinel chickens.

A dot enzyme-linked immunosorbent assay utilizing a novel membrane, polyvinylidene difluoride, is described. This assay was developed for the rapid detection of serum antibodies to eastern equine encephalomyelitis virus and St. Louis encephalitis virus in sentinel chickens. Antigens were spot-filtered through the membrane. Membranes were dipped into small vials of sera. Antigen-antibody complex...

متن کامل

Performance of immunoglobulin G (IgG) and IgM enzyme-linked immunosorbent assays using a West Nile virus recombinant antigen (preM/E) for detection of West Nile virus- and other flavivirus-specific antibodies.

Focus Technologies developed an indirect immunoglobulin G (IgG) enzyme-linked immunosorbent assay (ELISA) and a mu-capture IgM ELISA for the detection of West Nile virus (WNV)-specific antibodies based on a WNV preM/E protein recombinant antigen. Normal and disease state serum panels were used to assess the performance characteristics of the two WNV ELISA kits. Totals of 807 and 1,423 sera were...

متن کامل

Adaptation of an indirect enzyme-linked immunosorbent assay by purified gp51SU for detection of antibodies to bovine leukemia virus

The objective of this study was to compare an indirect ELISA, based on a purified 60 kDa envelope glycoprotein (gp51SU), with a Pourquire indirect ELISA for the detection of antibodies to the bovine leukemia virus. For conducting this research, 340 serum samples were collected from two different breeds of cows (Sarabi and Holestin) in different herds. Commercial ELISA revealed positive results ...

متن کامل

Standardization of an Enzyme-Linked Immunosorbent Assay for Detection of Infectious Bronchitis Virus Antibody.

An indirect enzyme–linked immunosorbent assay (ELISA) was developed for screening of antibody to avian infectious bronchitis virus (IBV). Antigen was prepared from whole-purified IBV Massachusetts serotype (BR 801 strain). Optimum dilution with minimum background for antigen concentration, rabbit anti-chicken conjugate and sera in developed ELISA was determined 0.1μg/ml, 1:3000 and 1:100, respe...

متن کامل

Duplex microsphere-based immunoassay for detection of anti-West Nile virus and anti-St. Louis encephalitis virus immunoglobulin m antibodies.

West Nile (WN) virus was introduced into the United States in 1999, when the first human cases of WN fever and encephalitis appeared in New York City. From there, the virus has spread throughout North America, in some areas cocirculating with the related flavivirus St. Louis encephalitis (SLE) virus. Public health laboratories currently use an immunoglobulin M (IgM) antibody capture enzyme-link...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 42 10  شماره 

صفحات  -

تاریخ انتشار 2004