Comparison of pencil beam and collapsed cone algorithms, in radiotherapy treatment planning for 6 and 10 MV photon.

نویسندگان

  • Saeed Ahmad Buzdar
  • M Afzal
  • Andrew Todd-Pokropek
چکیده

BACKGROUND In radiotherapy treatment, the calculation of radiation dose distribution in target volume lead to an optimum set of planning parameters. This worked has been aimed to compare two photon beam dose calculation algorithms in the Oncentra Treatment Planning system for Varian Linear Accelerator, to assure the quality of treatment planning. METHODS Monitor Units to be delivered on normalization depth in patient has been calculated using the pencil beam and collapsed cone algorithms for two photon energies 6 and 10 MV. The percentage depth dose and beam profiles for 21 treatment fields, for both the calculation systems have been compared for both photon energies. RESULTS The percentage depth doses and beam profiles for both calculation systems are comparable in large field sizes as well as central axis field settings. The doses normalization depth deviate for some field settings, but in central axis large field sizes the difference within tolerance limits. CONCLUSION Both calculation algorithms are in close agreement in most of the field settings (mainly in central axis fields), within tolerance level. The difference is relatively greater in small field sizes and off-axis field settings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Evaluation of Dose calculation algorithms of Monaco Treatment Planning System in the heterogeneities area

Introduction: In radiation therapy, the accuracy of dose calculations by a treatment planning system (TPS) is important to achieve tumor control and to spare normal tissue. Treatment planning system calculations in the heterogeneous situation may present significant inaccuracies. In this study, three different dose calculation algorithms, pencil beam (PB), collapsed cone (CC), ...

متن کامل

Calculation and Comparison of Heart Integral Dose in The Treatment of Esophagus Cancer with Three Photon Energies & Using CT Simulation and Treatment Planning System

Introduction: Esophageal cancer is one of the most frequently occurring cancers in Iran and having a  high  incidence  rate  among  other  countries.  Radiotherapy  is  one  of  the  three  methods  (surgery,  radiotherapy and chemotherapy) for radical or palliative treatment of esophageal cancer. In this method  of treatment, the organs such as heart and spinal cord are regarded as organs at r...

متن کامل

Evaluation of Three-dimensional Treatment Planning System (TPS) performance in dose calculation of virtual wedged fields using film dosimetry

Introduction: Nowadays radiotherapy plays an important role in cancer treatment. Different radiotherapy techniques improvement emphasizes on using of the precise ، appropriate and useful algorithms. one of these techniques are wedged which is used in radiotherapy to compensate missing tissues and create a uniform dose distribution in tissues. The Siemens Artiste linear accelera...

متن کامل

Comparison of radiotherapy techniques to reduce hematologic toxicity in whole pelvic radiation therapy

Introduction: Concurrent chemoradiotherapy (CRT) is a standard treatment method for patients with carcinoma of cervix. Despite admirable therapeutic results, acute hematologic toxicity (HT) is common with this regimen. Many studies evaluate the relationship between the bone marrow dosimetric parameters and the severity of HT and result shown that the low dose of bone marrow wou...

متن کامل

Evaluating Performance of Algorithms in Lung IMRT: A Comparison of Monte Carlo, Pencil Beam, Superposition, Fast Superposition and Convolution Algorithms

Background: Inclusion of inhomogeneity corrections in intensity modulated small fields always makes conformal irradiation of lung tumor very complicated in accurate dose delivery.Objective: In the present study, the performance of five algorithms via Monte Carlo, Pencil Beam, Convolution, Fast Superposition and Superposition were evaluated in lung cancer Intensity Modulated Radiotherapy plannin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Ayub Medical College, Abbottabad : JAMC

دوره 22 3  شماره 

صفحات  -

تاریخ انتشار 2010