Fast and reliable screening of mutations in human tumors: use of multiple fluorescence-based long linker arm nucleotides assay (mf-LLA).
نویسندگان
چکیده
Human tumor samples were screened for point mutations by adapting a mobility-shift assay to automated DNA sizing. This screen identifies the type of point mutation and relative amount of mutated DNA sequences present in a sample. Test samples having known hypoxanthine-guanine phosphoribosyl transferase (hprt)/exon-3 sequence mutations were characterized by: (i) PCR amplification, (ii) fluorescent dye-primer extension with 36-atom linker derived deoxycytosine or deoxyuridine triphosphate and the remaining three natural nucleotides and (iii) sizing of the resulting fluorescently labeled modified strands, using an automated DNA sequencer. Routinely, a range of sizes is observed among the sequence variants of a single DNA target sequence. This is because nucleotide analogs are incorporated into DNA strands in a sequence-dependent manner, resulting in composition-dependent electrophoretic mobility. Thus, point mutations are identified as shifts in mobility between the fluorescently labeled modified strands of the control and test samples. The twenty different hprt/exon-3 single-base substitution mutations tested were easily identified, even at fourfold dilution with control DNA.
منابع مشابه
Long non-coding RNAs and their significance in human diseases
Protein-coding genes account for only a small fraction of the human genome and most of the genomic sequences are transcriptionally silent, but recent observations indicate significant functional elements, including non-coding protein transcripts in the human genome. Long non-coding RNAs (lncRNAs) have been defined as transcripts of >200 nucleotides without protein-coding capacity that perform t...
متن کامل***Removed from the Issue*** Application of Cell-Based Assay Systems for the Early Screening of Human Drug Hepatotoxicity in the Discovery Phase of Drug Development
متن کامل
***Removed from the Issue*** Application of Cell-Based Assay Systems for the Early Screening of Human Drug Hepatotoxicity in the Discovery Phase of Drug Development
متن کامل
Multi-Fluorescence Real-Time PCR Assay for Detection of RIF and INH Resistance of M. tuberculosis
BACKGROUND Failure to early detect multidrug-resistant tuberculosis (MDR-TB) results in treatment failure and poor clinical outcomes, and highlights the need to rapidly detect resistance to rifampicin (RIF) and isoniazid (INH). METHODS In Multi-Fluorescence quantitative Real-Time PCR (MF-qRT-PCR) assay, 10 probes labeled with four kinds of fluorophores were designed to detect the mutations in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BioTechniques
دوره 26 6 شماره
صفحات -
تاریخ انتشار 1999