A CAD/CAM Zirconium Bar as a Bonded Mandibular Fixed Retainer: A Novel Approach with Two-Year Follow-Up

نویسندگان

  • Maen Zreaqat
  • Rozita Hassan
  • Abdul Fatah Hanoun
چکیده

Stainless steel alloys containing 8% to 12% nickel and 17% to 22% chromium are generally used in orthodontic appliances. A major concern has been the performance of alloys in the environment in which they are intended to function in the oral cavity. Biodegradation and metal release increase the risk of hypersensitivity and cytotoxicity. This case report describes for the first time a CAD/CAM zirconium bar as a bonded mandibular fixed retainer with 2-year follow-up in a patient who is subjected to long-term treatment with fixed orthodontic appliance and suspected to have metal hypersensitivity as shown by the considerable increase of nickel and chromium concentrations in a sample of patient's unstimulated saliva. The CAD/CAM design included a 1.8 mm thickness bar on the lingual surface of lower teeth from canine to canine with occlusal rests on mesial side of first premolars. For better retention, a thin layer of feldspathic ceramic was added to the inner surface of the bar and cemented with two dual-cured cement types. The patient's complaint subsided 6 weeks after cementation. Clinical evaluation appeared to give good functional value where the marginal fit of digitized CAD/CAM design and glazed surface offered an enhanced approach of fixed retention.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A single-retainer zirconium dioxide ceramic resin-bonded fixed partial denture for single tooth replacement: a clinical report.

This clinical report describes a treatment for the replacement of a missing mandibular anterior tooth using a cantilever single-retainer resin-bonded fixed partial denture (RBFPD), fabricated from zirconium dioxide (ZrO2) ceramic. No clinical complications were observed at the 2-year 6-month follow-up examination after placement of the ZrO2 ceramic RBFPD, and satisfactory functional and estheti...

متن کامل

Fabrication of the mandibular implant-supported fixed restoration using CAD/CAM technology: a clinical report.

The mandibular implant-supported fixed restoration is an appropriate treatment choice for patients with inadequate bone volume in the posterior mandible. Computer-aided design/computer-aided manufacturing (CAD/CAM) technology has broadened the scope and application for this treatment option. A milled titanium bar retaining individual all-ceramic zirconium oxide crowns, with composite resin repl...

متن کامل

SHORT COMMUNICATION Unexpected complications of bonded mandibular lingual retainers

Introduction: The flexible spiral wire (FSW) retainer is the most frequently used type of fixed retainer bonded on all 6 anterior teeth. Our aim in this article was to demonstrate unexpected posttreatment changes in the labiolingual position of the mandibular anterior teeth associated with the use of FSW retainers. Methods: During a 3-year period, patients attending the postgraduate orthodontic...

متن کامل

Assessing the feasibility of yttria-stabilized zirconia in novel designs as mandibular anterior fixed lingual retention after orthodontic treatment.

INTRODUCTION The purpose of this study is to explore the feasibility of yttria-stabilized zirconia (Y-TZP) in fixed lingual retention as an alternative to stainless steel. METHODS Exploratory Y-TZP specimens were milled to establish design parameters. Next, the specimens were milled according to ASTM standard C1161-13 and subjected to 4-point flexural tests to determine material properties. F...

متن کامل

Clinical evaluation of bond failures and survival between mandibular canine-to-canine retainers made of flexible spiral wire and fiber-reinforced composite

OBJECTIVES The purpose of this longitudinal prospective randomized study was to evaluate the clinical reliability of two different types of postorthodontic treatment retainers: a silanised-treated glass fibers-reinforced resin composite (FRC) and a directly bonded multistranded stainless steel wire. The hypothesis of the study was to assess if significant differences are present between failure...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017