Effect of acute human cardiac allograft rejection on left ventricular systolic torsion and diastolic recoil measured by intramyocardial markers.

نویسندگان

  • D E Hansen
  • G T Daughters
  • E L Alderman
  • E B Stinson
  • J C Baldwin
  • D C Miller
چکیده

Left ventricular systolic torsion and diastolic recoil were quantified in 12 human cardiac transplant recipients with surgically implanted intramyocardial markers with the use of computer-aided analysis of biplane cineradiographic images. Measurements were performed between 6 and 16 weeks after surgery and related to the presence or absence of rejection as determined by cardiac biopsy. Torsional deformation, defined as twisting about the left ventricular long axis of the apical region with respect to the base, was characterized in terms of the rate and amplitude of systolic torsion and the rate of diastolic recoil by means of an internal reference system. Comparison of measurements before, during, and after recovery from 14 rejection episodes allowed assessment of the effects of acute reversible cardiomyopathy on left ventricular torsion and recoil. Compared with prerejection values, the amplitude of torsional deformation in the maximally deforming segment (theta max) decreased by 25% from 21.1 +/- 15.2 to 16.0 +/- 5.7 degrees (p less than .005) during acute rejection with myocyte necrosis; this was associated with significant (p less than .05) decreases in the peak systolic torsion rate (+d theta/dtmax), whereas the peak diastolic recoil rate (-d theta/dtmax) was unchanged. This suggests that the stiffness of elastic components of the myocardium may have increased, maintaining the rate of diastolic recoil when these elements are stretched less. With successful treatment of rejection episodes, the torsional deformation characteristics normalized. Heart rate, mean arterial pressure, left ventricular end-diastolic volume, stroke volume, ejection fraction, and peak left ventricular filling rate were unchanged with rejection episodes, whereas left ventricular end-systolic volume increased (p less than .05) during acute rejection and returned to normal with resolution of the rejection process. These data suggest that left ventricular torsional deformation amplitude and rate are sensitive to episodes of subclinical left ventricular dysfunction and that such intramyocardial marker techniques may provide new insights regarding the elastic properties of the ventricular myocardium and their impact on left ventricular mechanics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PATHOPHYSIOLOGY AND NATURAL HISTORY CARDIAC TRANSPLANTATION Effect of acute human cardiac allograft rejection on left ventricular systolic torsion and diastolic recoil measured by intramyocardial markers

Left ventricular systolic torsion and diastolic recoil were quantified in 12 human cardiac transplant recipients with surgically implanted intramyocardial markers with the use of computer-aided analysis of biplane cineradiographic images. Measurements were performed between 6 and 16 weeks after surgery and related to the presence or absence of rejection as determined by cardiac biopsy. Torsiona...

متن کامل

Left Ventricular Diastolic Twist Mechanics During Acute Human Cardiac Allograft Rejection

Background. Contraction of obliquely oriented left ventricular (LV) fibers results in a twisting motion of the left ventricle. The purpose of this study was to assess the effects of acute human cardiac allograft rejection on LV twist pattern and the twist-volume relation. Methods and Results. Tantalum markers were implanted into the LV midwall in 15 transplant recipients to measure time-varying...

متن کامل

Alterations in left ventricular diastolic twist mechanics during acute human cardiac allograft rejection.

BACKGROUND Contraction of obliquely oriented left ventricular (LV) fibers results in a twisting motion of the left ventricle. The purpose of this study was to assess the effects of acute human cardiac allograft rejection on LV twist pattern and the twist-volume relation. METHODS AND RESULTS Tantalum markers were implanted into the LV midwall in 15 transplant recipients to measure time-varying...

متن کامل

The Correlation between Left and Right Ventricular Ejection Fractions in Patients with Ischemic Heart Disease, Documented by Cardiac Magnetic Resonance Imaging

Introduction: The correlation between right and left ventricular ejection fractions (RVEF and LVEF, respectively) has been studied in only a small number of patients with a marked decrease in RVEF and LVEF. The aim of the present study was to compare LVEF and RVEF in patients with ischemic heart disease. RVEF and LVEF were measured by Cardiovascular Magnetic Resonance (CMR) imaging. Materials a...

متن کامل

The Impact of Cardiac Rehabilitation on Pulmonary Artery Systolic Pressure and Left Ventricular End-Diastolic Pressure in Patients after Coronary Artery Bypass Graft Surgery

Background:Cardiac rehabilitation program (CRP) is a useful method of modifying cardiovascular risk factors, improving life expectancy and quality of life in patients with ischemic heart disease (IHD). The present study was conducted to evaluate the effects of cardiac rehabilitation on the pulmonary artery systolic pressure (PASP) and left ventricular end-diastolic pressure (LV...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 76 5  شماره 

صفحات  -

تاریخ انتشار 1987