Skinfold thickness affects the isometric knee extension torque evoked by Neuromuscular Electrical Stimulation
نویسندگان
چکیده
BACKGROUND Subcutaneous adipose tissue may influence the transmission of electrical stimuli through to the skin, thus affecting both evoked torque and comfort perception associated with neuromuscular electrical stimulation (NMES). This could seriously affect the effectiveness of NMES for either rehabilitation or sports purposes. OBJECTIVE To investigate the effects of skinfold thickness (SFT) on maximal NMES current intensity, NMES-evoked torque, and NMES-induced discomfort. METHOD First, we compared NMES current intensity, NMES-induced discomfort, and NMES-evoked torque between two subgroups of subjects with thicker (n=10; 20.7 mm) vs. thinner (n=10; 29.4 mm) SFT. Second, we correlated SFT to NMES current intensity, NMES-induced discomfort, and NMES-evoked knee extension torque in 20 healthy women. The NMES-evoked torque was normalized to the maximal voluntary contraction (MVC) torque. The discomfort induced by NMES was assessed with a visual analog scale (VAS). RESULTS NMES-evoked torque was 27.5% lower in subjects with thicker SFT (p=0.01) while maximal current intensity was 24.2% lower in subjects with thinner SFT (p=0.01). A positive correlation was found between current intensity and SFT (r=0.540, p=0.017). A negative correlation was found between NMES-evoked torque and SFT (r=-0.563, p=0.012). No significant correlation was observed between discomfort scores and SFT (rs=0.15, p=0.53). CONCLUSION These results suggest that the amount of subcutaneous adipose tissue (as reflected by skinfold thickness) affected NMES current intensity and NMES-evoked torque, but had no effect on discomfort perception. Our findings may help physical therapists to better understand the impact of SFT on NMES and to design more rational stimulation strategies.
منابع مشابه
Effect of the simultaneous application of NMES and HVPC on knee extension torque.
CONTEXT Electrical stimulation using simultaneous application of two current types for multiple effects is a current treatment option, but the effect of this treatment is not currently known. OBJECTIVES To compare isometric knee extension torque when using neuromuscular electrical stimulation (NMES) in combination with High Voltage Pulsed Current (HVPC) versus NMES alone during three contract...
متن کاملMaximal Voluntary and Electrically Stimulated Torque – Angle – Angular Velocity Profiles of the Knee Extensors and Flexors
In vivo measurements of maximum voluntary force – velocity show differences to the in vitro tetanic profile, with eccentric forces not increasing much above isometric and tending to decline with increasing lengthening velocity. Using transcutaneous electrical stimulation maximal eccentric torque has been found to be 1.4 times the isometric value and does not drop off at higher eccentric velocit...
متن کاملEffects of neuromuscular electrical stimulation and low-level laser therapy on neuromuscular parameters and health status in elderly women with knee osteoarthritis: A randomized trial.
OBJECTIVE To determine the effects of neuromuscular electrical stimulation and low-level laser therapy on neuromuscular parameters and health status in elderly subjects with knee osteoarthritis. DESIGN A randomized evaluator-blinded clinical trial. SUBJECTS Forty-five elderly women with knee osteoarthritis. METHODS Subjects were randomized into 1 of the following 3 intervention groups: el...
متن کاملThe effect of fatigue on the timing of electrical stimulation-evoked muscle contractions in people with spinal cord injury.
This study investigated the activation dynamics of electrical stimulation-evoked muscle contractions performed by individuals with spinal cord injury (SCI). The purpose was to determine whether electrical stimulation (ES) firing patterns during cycling exercise should be altered in response to fatigue-induced changes in the time taken for force to rise and fall with ES. Seven individuals with S...
متن کاملEstimation of Electrically-Evoked Knee Torque from Mechanomyography Using Support Vector Regression
The difficulty of real-time muscle force or joint torque estimation during neuromuscular electrical stimulation (NMES) in physical therapy and exercise science has motivated recent research interest in torque estimation from other muscle characteristics. This study investigated the accuracy of a computational intelligence technique for estimating NMES-evoked knee extension torque based on the M...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 19 شماره
صفحات -
تاریخ انتشار 2015