Multi-institutional analysis of computed and direct radiography: part II. Economic analysis.

نویسندگان

  • Bruce I Reiner
  • David Salkever
  • Eliot L Siegel
  • Frank J Hooper
  • Khan M Siddiqui
  • Amy Musk
چکیده

PURPOSE To compare economic aspects of equipment configurations, productivity levels, and patient waiting times in the performance of computed radiography (CR) and direct radiography (DR). MATERIALS AND METHODS The study received internal review board exemption status, without the need for informed patient consent. Data from four study sites were used to calculate the CR-DR crossover point (defined as the point at which the cost-effectiveness of DR equals that of CR) and CR-DR annual cost differentials. Analyzed variables included equipment and operating costs, examination volumes, and productivity. A program was developed to simulate patient arrival times, number of patient examinations, and patient waiting times on the basis of average annualized parameters for each of the four clinics. Sensitivity analyses were conducted to assess utilization rates and determine cost optimization. Utilization rates were compared with the number of excess long-stay CR patients (ie, patients who spent more than 30 minutes waiting in the radiology department prior to CR examination) and with the cost (per excess long-stay CR patient who waited more than 60 minutes) averted by using DR. RESULTS Excess annual costs for DR over CR at the four sites ranged from $50,757 to $75,303. At extrapolated levels of economic penalties for long waiting times, the crossover point at which the DR cost became justifiable was when CR capacity utilization rates approached or exceeded 80%. CONCLUSION In the current practice environment, with capacity utilization rates well below 80%, CR is likely to be a more cost-effective technology for the majority of general radiography providers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality comparison of direct digital panoramic radiography and computed radiography panoramic

BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...

متن کامل

Exergo-environmental and exergo-economic analyses and multi-criteria optimization of a novel solar-driven CCHP based on Kalina cycle

The present research proposes and optimizes the performance of a novel solar-driven combined cooling, heating, and power (CCHP) Kalina system for two seasons—winter and summer—based on exergy, exergo-economic, and exergo-environmental concepts applying a Non-dominated Sort Genetic Algorithm-II (NSGA-II) technique. Three criteria, i.e. daily exergy efficiency, total product cost rate, and to...

متن کامل

Exergo-environmental and exergo-economic analyses and multi-criteria optimization of a novel solar-driven CCHP based on Kalina cycle

The present research proposes and optimizes the performance of a novel solar-driven combined cooling, heating, and power (CCHP) Kalina system for two seasons—winter and summer—based on exergy, exergo-economic, and exergo-environmental concepts applying a Non-dominated Sort Genetic Algorithm-II (NSGA-II) technique. Three criteria, i.e. daily exergy efficiency, total product cost rate, and to...

متن کامل

Multi-objective Economic-statistical Design of Cumulative Count of Conforming Control Chart

Cumulative Count of Conforming (CCC) charts are utilized for monitoring the quality characteristics in high-quality processes. Executive cost of control charts is a motivation for researchers to design them with the lowest cost. Usually in most researches, only one objective named cost function is minimized subject to statistical constraints, which is not effective method for economic-statistic...

متن کامل

شناسایی و تحلیل تاثیر متغیرها و شاخص‌های تاب‌آوری: شواهدی از شمال و شمال‌شرقی تهران

Human communities are affected by hazards, disasters and catastrophic events throughout history, including natural disasters (such as: earthquakes, hurricanes, floods, tornadoes) man-made disasters (such as: nuclear accidents, explosions, socio or political crisis, economic disturbances). Therefore, catastrophic events can have human or natural causes. These conditions show that human communiti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 236 2  شماره 

صفحات  -

تاریخ انتشار 2005