Development of an analytical procedure for determination of selected estrogens and progestagens in water samples.
نویسندگان
چکیده
An analytical procedure has been developed for determination of eight selected natural and synthetic hormonal steroids in surface water and in effluent samples. Several methodological points have been investigated and are discussed; they include the choice of the solid-phase extraction sorbent, the influence of flow rate on recovery, the breakthrough volume for a given sorbent (Env+ and Oasis HLB), sample clean up, and sample storage. As regards the latter point, it was found that when no preservative was added to effluent from a sewage-treatment plant, severe loss of steroids occurred-85% of progesterone and about 30% of both estrone and estradiol were found to be degraded in 24 h. The procedure developed was applied to samples from the Seine river estuary. Sex steroids were not detected in surface water; estrone was the most commonly detected steroid in sewage-treatment plant effluent, with levels ranging from 1.8 to 8.3 ng L(-1). Synthetic estrogens (ethynylestradiol and mestranol) and progestagens (levonorgestrel and norethindrone) were never detected, whatever the sampling season. Overall, for 162 out of 168 measurements levels were below the detection limits of the developed procedure.
منابع مشابه
Air-assisted Liquid Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry for Preconcentration and Determination of Trace Amount of Co(II) and Ni(II) Ions in Water Samples
A simple, rapid and efficient method has been developed for the extraction, preconcentration and determination of cobalt (II) and nickel (II) ions in water samples by air-assisted liquid-liquid microextraction (AALLME) coupled with graphite furnace atomic absorption spectrometry (GFAAS). In the proposed method, much less volume of an organic solvent was used as the extraction solvent in the abs...
متن کاملIonic Liquid-based Ultrasound-assisted In-situ Solvent Formation Microextraction and High-performance Liquid Chromatography for the Trace Determination of Polycyclic Aromatic Hydrocarbons in Environmental Water Samples
A green and efficient ionic liquid-based ultrasound-assisted in-situ solvent formationmicroextraction (IL-UA-ISFME) in combination with high-performance liquid chromatographyultravioletdetection (HPLC-UV) has been successfully developed for the trace determination offive selected polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. In thismethod, a hydrophobic ionic liquid (1...
متن کاملValidation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS
Dispersive liquid liquid microextraction (DLLME) combined with gas chromatography–mass spectrometry (GC–MS) was used for the extraction and determination of 13 polycyclic aromatic hydrocarbons (PAHs) in mineral water samples. In this procedure, the suitable combination of extraction solvent (500 µL chloroform) and disperser solvent (1000 µL acetone) were quickly injected into the water sample (...
متن کاملValidation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS
Dispersive liquid liquid microextraction (DLLME) combined with gas chromatography–mass spectrometry (GC–MS) was used for the extraction and determination of 13 polycyclic aromatic hydrocarbons (PAHs) in mineral water samples. In this procedure, the suitable combination of extraction solvent (500 µL chloroform) and disperser solvent (1000 µL acetone) were quickly injected into the water sample (...
متن کاملVoltammetric Determination of Copper Ion in Water Samples Using a Drop Casted Biopolymer
Poly-dopamine, inspired by biopolymers of mussels, is an adhesive catecholamine possessing low cytotoxicity and very good biocompatibility. In the present study, poly-dopamine nanoparticles (PDNP), as a biopolymer, were synthesized and characterized using FTIR spectroscopy, scanning electron microscopy and electrochemical methods. The drop casted PDNPs at the surface of carbon paste electrode (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical and bioanalytical chemistry
دوره 381 6 شماره
صفحات -
تاریخ انتشار 2005