Suspension effect and dynamic evaluation of the total surface bearing (TSB) trans-tibial prosthesis: a comparison with the patellar tendon bearing (PTB) trans-tibial prosthesis.

نویسندگان

  • H Narita
  • K Yokogushi
  • S Shii
  • M Kakizawa
  • T Nosaka
چکیده

X-ray and cineradiography measurements were used to compare the suspension effect and stability of a TSB trans-tibial prosthesis with an Icelandic Roll-On Silicone Socket (ICEROSS) system to that of a PTB trans-tibial prosthesis. The suspension effect was measured by the distance between the tibia and the socket in both suspension position and weight-bearing position in both type of prostheses. The suspension effect of the TSB prosthesis (2.53 +/- 0.90 cm) was superior to that of the PTB prosthesis (3.60 +/- 0.56 cm) (p < 0.05) by x-ray measurement. The suspension effect of the TSB prosthesis (0.1, 0.4, 0.72 cm) was superior to that of the PTB prosthesis (0.3, 0.48, 1.03 cm) (p < 0.01, p < 0.05) by cineradiographic measurement. The stability was measured as the angle between the axis of the tibia and the prosthesis at the time of heel contact and toe off. The angle change of the TSB prosthesis was statistically smaller than that of the PTB prosthesis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of prosthetics-orthotics principles to treatment of fractures.

1 School of Medicine, University of Miami, Jackson Memorial Hospital, Miami, Fla. 33152. Greater knowledge and understanding of bioengineering by the prosthetics and orthotics industries during the past twenty years have resulted in the development of highly functional and sophisticated appliances. For example, modern prostheses for lowerand upperextremity amputees are now designed with proper ...

متن کامل

Interface pressures and shear stresses: sagittal plane angular alignment effects in three trans-tibial amputee case studies.

Interface pressures and shear stresses at different sagittal plane angular alignment settings were measured on 3 trans-tibial amputee subjects ambulating with patellar-tendon-bearing total contact prostheses. Substantial socket-shank angular alignment modifications in the sagittal plane had minimal effect on stance phase peak interface pressures, though more substantial effects on stance phase ...

متن کامل

Outcome of fitting an ICEROSS prosthesis: views of trans-tibial amputees.

A report of the outcome of fitting ICEROSS prostheses to trans-tibial amputees from a subregional amputee rehabilitation centre is presented. This work has mainly concentrated on obtaining patients' own views to judge advantages and disadvantages of ICEROSS compared to their previous patellar-tendon-bearing (PTB) prostheses. Sixty-nine patients were entered for this study, but the results of th...

متن کامل

A pilot study to test the influence of specific prosthetic features in preventing trans-tibial amputees from walking like able-bodied subjects.

The purpose of this pilot investigation was to develop a method to test the influence of specific prosthetic features in preventing trans-tibial amputees from walking like able-bodied subjects. An able-bodied subject was fitted with a patellar-tendon-bearing orthosis incorporating several features of an amputee's prosthesis. Kinetic, kinematic and metabolic data were collected as features were ...

متن کامل

Seated-popliteal weight bearing prosthesis for a bilateral amputee.

Bilateral lower limb amputees suffer from a lack of stability when seated without prostheses due to lack of ground reaction forces through the stumps. In patients for whom ambulation is not a realistic goal, the seated-popliteal weight bearing prosthesis provides a solution for stability when seated in a wheelchair, without the problem of tibial pressure experienced with patellar-tendon-bearing...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Prosthetics and orthotics international

دوره 21 3  شماره 

صفحات  -

تاریخ انتشار 1997