Noninvasive optical method of measuring tissue and arterial saturation: an application to absolute pulse oximetry of the brain.

نویسندگان

  • M A Franceschini
  • E Gratton
  • S Fantini
چکیده

We present a frequency-domain optical method for real-time noninvasive measurement of absolute tissue and arterial saturation. This method is based on quantitative measurement of the tissue absorption spectrum (for tissue saturation) and of the amplitude of the arterial-pulsation-induced absorption oscillations (for arterial saturation) at eight wavelengths in the range 633-841 nm. We report results obtained from readings taken from the forehead of a healthy volunteer, showing baseline saturation values of 74.7+/-0.2% (tissue) and 96.9+/-0.5% (arterial). These values dropped to minimum values of 71.6+/-0.2% and 90.0+/-0.2% , respectively, after 1 min of reduced inspired oxygen concentration [10% (by volume) O(2) from a baseline value of 21% O(2) ].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Pulse Oximetry in the Early Detection of Congenital Heart Diseases in Newborns

Background: Congenital heart diseases, which are asymptomatic at birth, are the most important causes of infant mortality. This study aimed to evaluate the role of pulse oximetry in the early detection of congenital heart diseases among newborns.Methods: In this cross-sectional descriptive study, 1230 newborns who were born in university hospitals in an urban area of Iran were placed unde...

متن کامل

A New Family of Sensors for Pulse Oximetry

Since the early 1980s, when pulse oximetry was introduced, this noninvasive method of monitoring the arterial oxygen saturation level in a patient’s blood (SpO2) has become a standard method in the clinical environment because of its simple application and the high value of the information it gives nurses and doctors. It is as common in patient monitoring to measure the oxygen level in the bloo...

متن کامل

Correlation between Pulse Oximetry Oxygen Saturation (SpO2) and Measured Arterial Oxygen Saturation (SaO 2 ) and Arterial Oxygen Tension (PaOz) in Neonates

=Abstract=Pulse oximetry has recently been introduced as a method for continuous and non-invasive transcutaneous monitoring of arterial oxygen saturation in neonates. The purpose of our study was to determine the reliability, accuracy, and practicability of pulse oximetry for monitoring arterial oxygenation in sick newborn infants. Pulse oximetry oxygen saturation values (SpO2) were compared wi...

متن کامل

Comparative study of pulse oximetry, physical examination and echocardiography results in the diagnosis of congenital heart defects in neonates in the first 24 hours of life

Introduction: Congenital heart disease is the most common congenital anomaly. About 50% of Neonates with congenital heart disease are asymptomatic in the first few days of life and are not diagnosed on initial examination. Pulse oximetry is a non-invasive method that can show the percentage of oxygen saturation in the blood and congenital heart disease. Methods: This was a descriptive cross-se...

متن کامل

Pulse oximetry: theory and applications for noninvasive monitoring.

Noninvasive measurement of arterial oxygen saturation (SaO2) by pulse oximetry is widely acknowledged to be one of the most important technological advances in monitoring clinical patients. Pulse oximeters compute SaO2 by measuring differences in the visible and near infrared absorbances of fully oxygenated and deoxygenated arterial blood. Unlike clinical blood gas analyzers, which require a sa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 24 12  شماره 

صفحات  -

تاریخ انتشار 1999