Asymmetric behavior of severed microtubule ends after ultraviolet- microbeam irradiation of individual microtubules in vitro

نویسندگان

  • R A Walker
  • S Inoué
  • E D Salmon
چکیده

The molecular basis of microtubule dynamic instability is controversial, but is thought to be related to a "GTP cap." A key prediction of the GTP cap model is that the proposed labile GDP-tubulin core will rapidly dissociate if the GTP-tubulin cap is lost. We have tested this prediction by using a UV microbeam to cut the ends from elongating microtubules. Phosphocellulose-purified tubulin was assembled onto the plus and minus ends of sea urchin flagellar axoneme fragments at 21-22 degrees C. The assembly dynamics of individual microtubules were recorded in real time using video microscopy. When the tip of an elongating plus end microtubule was cut off, the severed plus end microtubule always rapidly shortened back to the axoneme at the normal plus end rate. However, when the distal tip of an elongating minus end microtubule was cut off, no rapid shortening occurred. Instead, the severed minus end resumed elongation at the normal minus end rate. Our results show that some form of "stabilizing cap," possibly a GTP cap, governs the transition (catastrophe) from elongation to rapid shortening at the plus end. At the minus end, a simple GTP cap is not sufficient to explain the observed behavior unless UV induces immediate recapping of minus, but not plus, ends. Another possibility is that a second step, perhaps a structural transformation, is required in addition to GTP cap loss for rapid shortening to occur. This transformation would be favored at plus, but not minus ends, to account for the asymmetric behavior of the ends.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Metastable Intermediate State of Microtubule Dynamic Instability That Differs Significantly between Plus and Minus Ends

The current two-state GTP cap model of microtubule dynamic instability proposes that a terminal crown of GTP-tubulin stabilizes the microtubule lattice and promotes elongation while loss of this GTP-tubulin cap converts the microtubule end to shortening. However, when this model was directly tested by using a UV microbeam to sever axoneme-nucleated microtubules and thereby remove the microtubul...

متن کامل

The Effect of the Crocus Sativus L. Carotenoid, Crocin, on the Polymerization of Microtubules, in Vitro

Objective(s): Crocin, as the main carotenoid of saffron, has shown anti-tumor activity both in vitro and in vivo. Crocin might interact with cellular proteins and modulate their functions, but the exact target of this carotenoid and the other compounds of the saffron have not been discovered yet. Microtubular proteins, as one of the most important proteins inside the cells, have several functio...

متن کامل

INTRODUCTION Poleward flux of tubulin molecules in kinetochore microtubules of metaphase cells was demonstrated as poleward movement of locally uncaged fluorescent tubulin in vivo

Poleward flux of tubulin molecules in kinetochore microtubules of metaphase cells was demonstrated as poleward movement of locally uncaged fluorescent tubulin in vivo (Mitchison, 1989; Mitchison and Salmon, 1992; Zhai et al., 1995) and in reconstituted spindles in vitro (Sawin and Mitchison, 1991; Desai et al., 1998). Thus, tubulin polymerization occurs at the kinetochore (plus) ends of kinetoc...

متن کامل

Ultraviolet microbeam irradiation

Marginal bands were isolated from newt red blood cells and, using monochromatic light from an ultraviolet microbeam, the marginal band microtubules were irradiated in vitro to produce areas of reduced birefringence (ARBs). The ARBs neither moved nor changed shape after they were formed, though the marginal bands sometimes changed shape during the irradiation. Marginal band ARBs 'were regions in...

متن کامل

Effects of dynein on microtubule mechanics and centrosome positioning

To determine forces on intracellular microtubules, we measured shape changes of individual microtubules following laser severing in bovine capillary endothelial cells. Surprisingly, regions near newly created minus ends increased in curvature following severing, whereas regions near new microtubule plus ends depolymerized without any observable change in shape. With dynein inhibited, regions ne...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of Cell Biology

دوره 108  شماره 

صفحات  -

تاریخ انتشار 1989